Twenty‐eight day Holter monitoring is poorly tolerated and insensitive for paroxysmal atrial fibrillation detection in cryptogenic stroke
Authors:
- 12 May 2014
- journal article
- clinical trial
- Published by Wiley in Internal Medicine Journal
- Vol. 44 (5) , 505-508
Abstract
This pilot study in a prospective cohort of 20 cryptogenic stroke patients showed that a significant proportion has paroxysmal atrial fibrillation undetected by 24‐h Holter monitoring. However, longer monitoring with 28‐day Holter was poorly tolerated and still insufficiently sensitive for paroxysmal atrial fibrillation detection. Further studies are urgently needed to elucidate the optimal timing, method and duration of cardiac rhythm monitoring following ischaemic stroke.Keywords
This publication has 17 references indexed in Scilit:
- Paroxysmal Atrial Fibrillation in Cryptogenic Stroke: A Case–Control StudyJournal of Stroke and Cerebrovascular Diseases, 2013
- Occult Atrial Fibrillation in Cryptogenic StrokeStroke, 2013
- Incidence of atrial fibrillation detected by implantable loop recorders in unexplained strokeNeurology, 2013
- Oral Antithrombotic Agents for the Prevention of Stroke in Nonvalvular Atrial FibrillationStroke, 2012
- Detection of Paroxysmal Atrial Fibrillation by 30-Day Event Monitoring in Cryptogenic Ischemic StrokeStroke, 2012
- Prolonged Rhythm Monitoring for the Detection of Occult Paroxysmal Atrial Fibrillation in Ischemic Stroke of Unknown CauseCirculation, 2011
- Frequent Atrial Premature Beats Predict Paroxysmal Atrial Fibrillation in Stroke PatientsStroke, 2007
- ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial FibrillationCirculation, 2006
- Differences in Vascular Risk Factors Between Etiological Subtypes of Ischemic StrokeStroke, 2003
- Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment.Stroke, 1993