Non-invasive hemodynamic monitoring in trauma patients
Open Access
- 8 March 2015
- journal article
- review article
- Published by Springer Nature in World Journal of Emergency Surgery
- Vol. 10 (1) , 11
Abstract
The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m2 to -0.14 +/- 0.73 l/min/m2. Additionally, data on practicality, limitations and clinical impact of the devices were collected. The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.Keywords
This publication has 18 references indexed in Scilit:
- Cardiac Output Monitoring: Is There a Gold Standard and How Do the Newer Technologies Compare?Seminars in Cardiothoracic and Vascular Anesthesia, 2010
- Noninvasive Cardiac Output Determination: Broadening the Applicability of Hemodynamic MonitoringSeminars in Cardiothoracic and Vascular Anesthesia, 2009
- Noninvasive Monitoring of the Autonomic Nervous System and Hemodynamics of Patients With Blunt and Penetrating TraumaJournal of Trauma: Injury, Infection & Critical Care, 2008
- Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactanceAmerican Journal of Physiology-Heart and Circulatory Physiology, 2007
- Hemodynamic Patterns of Blunt and Penetrating InjuriesJournal of the American College of Surgeons, 2006
- Evaluation of Invasive and Noninvasive Hemodynamic Monitoring in Trauma Patients2006
- Survival, Hemodynamics, and Tissue Oxygenation after Head TraumaJournal of the American College of Surgeons, 2006
- Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patientsJournal of Pediatric Surgery, 2005
- Is Noninvasive Hemodynamic Monitoring Appropriate for the Elderly Critically Injured Patient?2005
- Noninvasive Cardiac Index Monitoring in Gunshot Wound VictimsAcademic Emergency Medicine, 1996