Comparison of Phase-Screen and Geometry-Based Phase Aberration Correction Techniques for Real-Time Transcranial Ultrasound Imaging
Open Access
- 10 October 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 10183
Abstract
While transcranial ultrasound imaging is a promising diagnostic modality, it is still hindered due to phase aberration and multiple scattering caused by the skull. In this paper, we compare near-field phase-screen modeling (PS) to a geometry-based phase aberration correction technique (GB) when an ultrafast imaging sequence (five plane waves tilted from −15 to +15 degrees in the cutaneous tissue layer) is used for data acquisition. With simulation data, the aberration profile (AP) of two aberrator models (flat and realistic temporal bone) was estimated in five isoplanatic patches, while the wave-speed of the brain tissue surrounding the point targets was either modeled homogeneously (ideal) or slightly heterogeneously to generate speckle (for mimicking a more realistic brain tissue). For the experiment, a phased array P4-1 transducer was used to image a wire phantom; a 4.2-mm-thick bone-mimicking plate was placed in front of the probe. The AP of the plate was estimated in three isoplanatic patches. The numerical results indicate that, while all the scatterers are detectable in the image reconstructed by the GB method, many scatterers are not detected with the PS method when the dataset used for AP estimation is generated with a realistic bone model and heterogeneous brain tissue. The experimental results show that the GB method increases the signal-to-clutter ratio (SCR) by 7.5 dB and 6.5 dB compared to the PS and conventional reconstruction methods, respectively. The GB method reduces the axial/lateral localization error by 1.97/0.66 mm and 2.08/0.7 mm compared to the PS method and conventional reconstruction, respectively. The lateral spatial resolution (full-width-half-maximum) is also improved by 0.1 mm and 1.06 mm compared to the PS method and conventional reconstruction, respectively. Our comparison study suggests that GB aberration correction outperforms the PS method when an ultrafast multi-angle plane wave sequence is used for transcranial imaging with a single transducer.Keywords
Funding Information
- Netherlands Organisation for Scientific Research (NWO) (116310008)
This publication has 41 references indexed in Scilit:
- Transcranial ultrasound imaging with speed of sound-based phase correction: a numerical studyPhysics in Medicine & Biology, 2013
- Time-reversal transcranial ultrasound beam focusing using a k-space methodPhysics in Medicine & Biology, 2012
- Attenuation, scattering, and absorption of ultrasound in the skull boneMedical Physics, 2011
- k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fieldsJournal of Biomedical Optics, 2010
- Real-Time 3-D Contrast-Enhanced Transcranial Ultrasound and Aberration CorrectionUltrasound in Medicine & Biology, 2008
- Discontinuing Prophylactic Transfusions Used to Prevent Stroke in Sickle Cell DiseaseNew England Journal of Medicine, 2005
- Physical and technical aspects of ultrasonic brain imaging through thick skull bones: 2. Experimental studiesAcoustical Physics, 2003
- Physical and technological aspects of ultrasonic imaging of brain structures through thick skull bones: 1. Theoretical and model studiesAcoustical Physics, 2003
- Transcranial Doppler correlation with cerebral angiography in sickle cell disease.Stroke, 1992
- Distribution of Angiographic Vasospasm after Subarachnoid Hemorrhage: Implications for Diagnosis by Transcranial Doppler UltrasonographyNeurosurgery, 1990