Impact of quality indicators on variability of keratometry measurements using a SS-OCT–based optical biometer
- 1 January 2025
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (1) , 16-22
Abstract
Purpose: To characterize the variability of keratometry measurements on the IOLMaster 700 and relate it to device image quality indicators (QIs). Setting: 2 academic centers and 1 private practice. Design: Multicenter, retrospective consecutive case series. Methods: Measurements from 3 sites, obtained between December 2015 and July 2023, were included. Surgery-naïve phakic eyes with same-day sequential measurements on the same eye were identified. Repeat measurement pairs were grouped by IOLMaster QIs (success vs warning), and changes in mean standard keratometry (∆Kmean) and total keratometry (∆TKmean) as well as standard astigmatism (∆Kastig) and total astigmatism (∆TKastig) vectors were calculated. Results: Analysis was performed on 3222 eyes of 1890 patients. Measurement “success” was associated with a smaller ΔKmean (0.09 ± 0.14 diopters [D]) and ΔTKmean (0.11 ± 0.16 D) when compared with pairs in which both measurements had a “warning” (0.25 ± 0.32 D and 0.14 ± 0.17 D, respectively; P < .0001). A similarly smaller ∆Kastig (0.26 ± 0.28 D) and ∆TKastig (0.28 ± 0.30 D) were observed with measurement “success” vs “warning” (0.77 ± 0.79 D and 0.42 ± 0.41 D, respectively; P < .0001). Even when both measurements were successful, the proportion of measurement pairs that had a ∆Kastig >0.50 D increased from 14% to 24% to 32% when Kmean SD was ≥0.01, 0.05, and 0.10 D, respectively. Conclusions: When measurement quality is poor, TK varies less than standard K measurements. Clinicians may use the SD of Kmean/TKmean to estimate the repeatability of measurements and balance this against their tolerance for performing repeat measurements.Keywords
This publication has 18 references indexed in Scilit:
- Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculationInternational Ophthalmology, 2021
- Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imagingEye, 2020
- Pursuing perfection in intraocular lens calculationsJournal of Cataract & Refractive Surgery, 2018
- Pursuing perfection in IOL calculations. II. Measurement foibles: Measurement errors, validation criteria, IOL constants, and lane lengthJournal of Cataract & Refractive Surgery, 2017
- Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry deviceJournal of Cataract & Refractive Surgery, 2016
- Keratometry versus total corneal refractive power: Analysis of measurement repeatability with 5 different devices in normal eyes with low astigmatismJournal of Cataract & Refractive Surgery, 2016
- Precision (repeatability and reproducibility) studies and sample-size calculationJournal of Cataract & Refractive Surgery, 2015
- Comparability and repeatability of corneal astigmatism measurements using different measurement technologiesJournal of Cataract & Refractive Surgery, 2012
- Origins of the Keratometer and its Evolving Role in OphthalmologySurvey of Ophthalmology, 2010
- Intraocular lens calculation formulas for new intraocular lens implantsJournal of Cataract & Refractive Surgery, 1987