Prospective Evaluation of Vascular Complications after Liver Transplantation: Comparison of Conventional and Microbubble Contrast-enhanced US
Authors:
- Ruchi ShresthaRSRuchi Shrestha
- Suzanne L. PalmerSPSuzanne L. Palmer
- Michael D. KatzMKMichael D. Katz
- R. Rick SelbyRSR. Rick Selby
- Zhanna AsatryanZAZhanna Asatryan
- Jabali K. WellsJWJabali K. Wells
- Edward G. GrantEGEdward G. Grant
- 1 October 2006
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (1) , 267-274
Abstract
To prospectively compare diagnostic performance of conventional Doppler ultrasonography (US) and microbubble contrast material-enhanced US for assessment of vascular complications after liver transplantation, with clinical follow-up or angiography as reference standard. This study was approved by institutional review board and was HIPAA compliant. Written informed consent was obtained. Seventy-two patients (49 men, 23 women; average age, 52.3 years) were included in this study. Patients who had undergone liver transplantation underwent conventional color Doppler and contrast-enhanced US of the liver. Quality of hepatic artery (HA) and portal vein (PV) visualization, contrast material arrival time, and time for complete evaluation of vasculature were compared for both techniques. McNemar test was used to compare vascular flow visualization scores; Student t test was used to compare mean study times with both techniques. Patients without HA flow at Doppler US underwent angiography; those with flow were followed up clinically. McNemar test was used to compare sensitivity of both techniques. Contrast-enhanced US helped significantly improve flow visualization in hepatic vessels (P < .001). Mean contrast material arrival time was 13.7 seconds +/- 3.8 (standard deviation) in proper HA and 20.7 seconds +/- 6.3 in PV. Mean study time decreased from 27.4 minutes +/- 13.9 to 9.3 minutes +/- 4.5 (P < .01). Doppler US failed to depict HA flow in eight patients; contrast-enhanced US showed flow in six and no flow in two of these patients. Follow-up results confirmed contrast-enhanced US findings. Sensitivity, specificity, and accuracy for Doppler US were 91.3%, 100%, and 91.5%, respectively. Sensitivity, specificity, and accuracy of contrast-enhanced US were all 100%. Sensitivity and accuracy values of the two techniques were significantly different (P < .014); there was no significant difference in specificity (P > .99) Contrast-enhanced US helped improve flow visualization in the HA and PV, decrease scanning time, and correctly differentiate between thrombosis and a patent artery in patients without HA flow at conventional Doppler US.Keywords
This publication has 10 references indexed in Scilit:
- Microbubble ultrasound contrast in the assessment of hepatic artery patency following liver transplantation: role in reducing frequency of hepatic artery arteriographyEuropean Radiology, 2004
- Ultrasound of Non-vascular Complications in the Post Liver Transplant PatientClinical Radiology, 2003
- Assessment of Portal Venous System Patency in the Liver Transplant Candidate: A Prospective Study Comparing Ultrasound, Microbubble-Enhanced Colour Doppler Ultrasound, with Arteriography and SurgeryClinical Radiology, 2002
- Contrast-enhanced ultrasound improves hepatic vessel visualization after orthotopic liver transplantationAbdominal Radiology, 2001
- Long-Term Survival After Liver Transplantation in 4,000 Consecutive Patients at a Single CenterAnnals of Surgery, 2000
- Hepatic artery stenosis and thrombosis in transplant recipients: Doppler diagnosis with resistive index and systolic acceleration time.Radiology, 1994
- Vascular complications after orthotopic liver transplantationThe American Journal of Surgery, 1991
- False-negative duplex Doppler studies in children with hepatic artery thrombosis after liver transplantation.American Journal of Roentgenology, 1990
- Duplex sonography of hepatic artery thrombosis after liver transplantationAmerican Journal of Roentgenology, 1988
- THE USE OF CONFIDENCE OR FIDUCIAL LIMITS ILLUSTRATED IN THE CASE OF THE BINOMIALBiometrika, 1934