Robust Control of a Cable-Driven Soft Exoskeleton Joint for Intrinsic Human-Robot Interaction
Authors:
- 1 March 2017
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 25 (7) , 976-986
Abstract
A novel, cable-driven soft joint is presented for use in robotic rehabilitation exoskeletons to provide intrinsic, comfortable human-robot interaction. The torque-displacement characteristics of the soft elastomeric core contained within the joint are modeled. This knowledge is used in conjunction with a dynamic system model to derive a sliding mode controller (SMC) to implement low-level torque control of the joint. The SMC controller is experimentally compared with a baseline feedback-linearised proportional-derivative controller across a range of conditions and shown to be robust to un-modeled disturbances. The torque controller is then tested with six healthy subjects while they perform a selection of activities of daily living, which has validated its range of performance. Finally, a case study with a participant with spastic cerebral palsy is presented to illustrate the potential of both the joint and controller to be used in a physiotherapy setting to assist clinical populations.Keywords
Funding Information
- Faculty of Engineering Research Development Fund, The University of Auckland
This publication has 31 references indexed in Scilit:
- Functional Elbow Range of Motion for Contemporary TasksJournal of Bone and Joint Surgery, 2011
- Force control of a robot for wrist rehabilitation: Towards coping with human intrinsic constraints2010
- Debridement Arthroplasty for Post-traumatic Stiff Elbow: Intraoperative Factors Affecting the Clinical Results of Surgical TreatmentClinics in Orthopedic Surgery, 2009
- Das Bewegungsausmaß der Schulter und des Ellenbogens bei Alltagsbewegungen in der 3D-BewegungsanalyseZeitschrift für Orthopädie und Unfallchirurgie, 2007
- Arm Rehabilitation Robot Impedance Control and Experimentation2006
- Robotic techniques for upper limb evaluation and rehabilitation of stroke patientsIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Adaptive robotic rehabilitation of locomotion: a clinical study in spinally injured individualsSpinal Cord, 2003
- The Coonrad-Morrey Total Elbow Arthroplasty in Patients Who Have Rheumatoid Arthritis. A Ten to Fifteen-Year Follow-up Study*Journal of Bone and Joint Surgery, 1998
- Anatomical Data for Analyzing Human MotionResearch Quarterly for Exercise and Sport, 1983
- Learned Helplessness: Performance as a Function of Task SignificanceThe Journal of Psychology, 1979