Negative predictive value of imaging-guided abdominal biopsy results: cytologic classification and implications for patient management.
Authors:
- S G SilvermanSSS G Silverman
- E S CibasECE S Cibas
- S E SeltzerSSS E Seltzer
- 1 September 1998
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 171 (3) , 693-696
Abstract
Our purpose was to assess the negative predictive value of imaging-guided abdominal biopsy results and correlate it with cytology classification, lesion size, needle gauge, and cancer history.A retrospective study was performed of 100 patients with proven diagnoses who had undergone imaging-guided abdominal biopsies showing no cells that were malignant or suspicious for malignancy. Specimens were classified as normal or benign, nondiagnostic, or atypical. Negative predictive value was calculated for each cytologic category, lesion size, needle gauge, and cancer history. Logistic regression analysis was performed to allow us to identify predictors of false-negative results.Overall negative predictive value was 67%. Other negative predictive values were normal or benign result, 78%; nondiagnostic result, 66%; and atypical result, 29%. Negative predictive value was greater when the lesion was large (> or =3 cm) (p = .031). Logistic regression analysis allowed us to predict a 9.3% chance of a false-negative r...Keywords
This publication has 9 references indexed in Scilit:
- Impact of positive findings at image-guided biopsy of lymphoma on patient care: evaluation of clinical history, needle size, and pathologic findings on biopsy performance.Radiology, 1994
- Predictive value of image-guided adrenal biopsy: analysis of results of 101 biopsies.Radiology, 1993
- Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value.Radiology, 1993
- CT and sonographically guided needle biopsy: current techniques and new innovations.American Journal of Roentgenology, 1990
- Image-directed percutaneous biopsies with a biopsy gun.Radiology, 1989
- Five years' experience of fine-needle aspiration biopsy: 454 consecutive casesClinical Radiology, 1985
- CT-guided liver biopsies: eight years' experience. Work in progress.Radiology, 1984
- Biopsy of focal hepatic lesions. Comparison of 18 and 22 gauge needles.Radiology, 1983
- Impact of fine-needle biopsy on management of patients with carcinoma of the pancreasAmerican Journal of Roentgenology, 1981