Long-term durability of bicuspid aortic valve repair: a comparison of 2 annuloplasty techniques
- 25 January 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 60 (2) , 286-294
Abstract
: OBJECTIVES: To compare long-term outcomes after bicuspid aortic valve (BAV) repair utilizing the Cabrol annuloplasty versus valve sparing Reimplantation technique. METHODS: From 1996 to 2018, 340 consecutive patients underwent BAV repair. Eighty underwent Cabrol annuloplasty and 189 underwent Reimplantation. Exclusion criteria were re-repairs (n = 6), active endocarditis (n = 4), no annuloplasty (n = 41) and ring or suture annuloplasty (n = 20). We compared both groups for survival, reoperations, valve related events and recurrent severe aortic regurgitation (AR > 2+). Inverse probability weighting (IPW) was used to balance the 2 groups. Cox regression analysis was used to identify outcome predictors. RESULTS: After weighting, pre- and intraoperative characteristics were similar between groups, except for aorta replacement techniques and operative time, which was longer in the Reimplantation group (P < 0.001). At 12 years, overall survival was similar between groups (IPW: Cabrol 97 ± 2% vs Reimplantation 94 ± 3%, P = 0.52). Freedom from reoperation and freedom from AR > 2+ were significantly lower in the Cabrol group (reoperation IPW: 69 ± 9% vs 91 ± 4%, P = 0.004 and AR > 2+ IPW: 71 ± 8% vs 97 ± 2%, P < 0.001). The Reimplantation technique was the only independent predictor of reoperation (hazard ratio 0.31; confidence interval 0.19–0.7; P = 0.005). CONCLUSIONS: In this study, comparing 2 annuloplasty strategies for BAV repair, we found statistically significant differences in long-term durability favouring the Reimplantation technique, and no differences in overall survival. The results support our current strategy of Reimplantation technique and repair of AR in patients with BAV. Cabrol annuloplasty is obsolete and should be generally abandoned in patients undergoing BAV repair for AR.Keywords
This publication has 27 references indexed in Scilit:
- Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic ValveCirculation, 2011
- Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity‐score matched samplesStatistics in Medicine, 2009
- Guidelines for reporting mortality and morbidity after cardiac valve interventionsThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Functional Anatomy of Aortic RegurgitationCirculation, 2007
- External Aortic Annuloplasty Ring for Valve-Sparing ProceduresThe Annals of Thoracic Surgery, 2005
- Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and doppler echocardiographyJournal of the American Society of Echocardiography, 2003
- Marginal Structural Models to Estimate the Joint Causal Effect of Nonrandomized TreatmentsJournal of the American Statistical Association, 2001
- An anatomic and physiologic approach to acquired heart disease8th Annual Meeting of the European Cardio-thoracic Association, The Hague, Netherlands, September 25–28, 1994European Journal of Cardio-Thoracic Surgery, 1995
- Aortic valve repairThe Annals of Thoracic Surgery, 1992
- Indications and limitations of aortic valve reconstructionThe Annals of Thoracic Surgery, 1991