Experimental analysis of the air velocity and contaminant dispersion of human exhalation flows
- 16 December 2016
- journal article
- research article
- Published by Wiley in Indoor Air
- Vol. 27 (4) , 803-815
Abstract
Human exhalation flow is a potential source of pathogens that can constitute a cross-infection risk to people in indoor environments. Thus, it is important to investigate the characteristics of this flow, its development, area of influence and the diffusion of the exhaled contaminants. This paper uses phase-averaged particle image velocimetry together with a tracer gas (CO2) to study two different exhalation flows over time: the exhalation of an average male (test M) and an average female (test F), using a life-sized thermal manikin in a supine position. The exhalation jets generated for both tests are similar in terms of symmetrical geometry, vorticity values, jet opening angles and velocity and concentration decays. However, there is a difference in the penetration length of the two flows throughout the whole exhalation process. There is also a time difference in reaching maximum velocity between the two tests. It is also possible to see that the tracer gas dispersion depends on the momentum of the jet so the test with the highest velocity decay shows the lowest concentration decay. All these results are of interest to better understand cross-infection risk.Keywords
Funding Information
- European Regional Development Fund
This publication has 45 references indexed in Scilit:
- Airflow Dynamics of Human Jets: Sneezing and Breathing - Potential Sources of Infectious AerosolsPLOS ONE, 2013
- Influenza Virus Aerosols in Human Exhaled Breath: Particle Size, Culturability, and Effect of Surgical MasksPLOS Pathogens, 2013
- Study on the initial velocity distribution of exhaled air from coughing and speakingChemosphere, 2012
- In China, Students in Crowded Dormitories with a Low Ventilation Rate Have More Common Colds: Evidence for Airborne TransmissionPLOS ONE, 2011
- Particle Image Velocimetry of Human CoughAerosol Science and Technology, 2011
- Simplified Model of Contaminant Dispersion in Rooms Conditioned by Chilled-Ceiling Displacement Ventilation SystemHVAC&R Research, 2010
- Research on the Air Stability of Limited SpaceInternational Journal of Green Energy, 2010
- Airborne transmission of disease in hospitalsJournal of The Royal Society Interface, 2009
- Influenza Virus in Human Exhaled Breath: An Observational StudyPLOS ONE, 2008
- Measurement and prediction of indoor air quality using a breathing thermal manikinIndoor Air, 2007