A parametric analysis of fixation post shape in tibial knee prostheses
Authors:
- Adrian B. LigginsALAdrian B. Liggins
- V. James RasoVRV. James Raso
- A. AmirfazliAAA. Amirfazli
- 8 December 2004
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 27 (2) , 123-134
Abstract
A primary concern of total knee replacement (TKR) is aseptic loosening of the tibial component, which may be caused by shielding of mechanical stresses in the bone and may require subsequent revision surgery. A three-dimensional (3D) finite element (FE) model has been developed to study bone and interface stresses for four different tibial prosthesis designs. The model described here incorporates orthotropic and heterogeneous bone properties with physiologically representative loading conditions. Results from this model indicate that stress distribution is affected by the incorporation of anisotropy and spatial variation of bone properties. All bone properties were mapped from published data to characterize their anisotropy and heterogeneity. Physiological loading was incorporated by mapping experimentally determined contact patterns. Convergence testing was performed to ensure model accuracy. In terms of interface forces, a tapered post decreased post shear while slightly increasing post compression compared to a cylindrical post; a post of elliptical cross-section increased post shear and decreased post compression. In terms of cancellous bone stress, tapered and elliptical posts both relieved compression compared to a cylindrical post, while a tapered post also produced increased peripheral stress. The inclusion of medial and lateral pegs in addition to a central fixation post caused localized stress shielding in the periphery of the pegs. In general, all implant models caused a reduction of cancellous bone stress plus high compression beneath the central fixation posts.Keywords
This publication has 37 references indexed in Scilit:
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Finite Element Analysis of Tibial Implants — Effect of Fixation Design and Friction ModelComputer Methods in Biomechanics and Biomedical Engineering, 2000
- The mechanical properties of trabecular bone: Dependence on anatomic location and functionJournal of Biomechanics, 1987
- A Three-Dimensional Finite Element Analysis of the Upper TibiaJournal of Biomechanical Engineering, 1986
- In Vitro Strain Distribution in the Proximal TibiaClinical Orthopaedics and Related Research, 1984
- A contact-coupled finite element analysis of the natural adult hipJournal of Biomechanics, 1984
- The mechanical properties of human tibial trabecular bone as a function of metaphyseal locationJournal of Biomechanics, 1983
- Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial EpiphysisJournal of Biomechanical Engineering, 1982
- Analysis of Model Variables and Fixation Post Length Effects on Stresses Around a Prosthesis in the Proximal TibiaJournal of Biomechanical Engineering, 1981
- Stresses in the human knee jointJournal of Biomechanics, 1976