Design and Dynamics of Oil Filled Flexural Ultrasonic Transducers for Elevated Pressures
Open Access
- 6 June 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (13) , 12673-12680
Abstract
The flexural ultrasonic transducer has traditionally been limited to proximity measurement applications, such as car-parking systems and industrial metrology. Principally, their classical form is unsuitable for environments above atmospheric 1 bar pressure, due to an internal air cavity which creates a pressure imbalance across the transducer’s vibrating membrane. This imbalance leads to physical deformation and degradation of the transducer’s structure, restricting the membrane’s capacity to vibrate at resonance to transmit and receive ultrasound. There is a requirement for ultrasonic sensors which can withstand environments of elevated pressure, for example in ultrasonic gas metering. Recent research demonstrated the dynamic performance of flexural ultrasonic transducers with vented structures, allowing the pressure to balance across the transducer membrane. However, a hermetically sealed transducer is a more practical and robust solution, where the internal components of the transducer, such as the piezoelectric ceramic disc, will be protected from harmful environmental fluids. In this research, the design and fabrication of a new form of flexural ultrasonic transducer for environments of elevated pressure is demonstrated, where the internal air cavity is filled with an incompressible fluid in the form of a non-volatile oil. Dynamic performance is measured through acoustic microphone measurements, electrical impedance analysis, and pulse-echo ultrasound measurement. Together with finite element analysis, stable ultrasound measurement is achieved above 200 bar in air, opening the possibility for reliable ultrasound measurement in hostile environments of elevated pressure.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/N025393/1)
This publication has 21 references indexed in Scilit:
- The electro-mechanical behaviour of flexural ultrasonic transducersApplied Physics Letters, 2017
- Multi-modal sensor fusion for indoor mobile robot pose estimation2016
- Experimental and simulation characterisation of flexural vibration modes in unimorph ultrasound transducersUltrasonics, 2016
- Effect of fluid losses and acoustic resonances in CMUTs with vented cavities2015
- Metal cap flexural transducers for air-coupled ultrasonicsAIP Conference Proceedings, 2015
- Review of air-coupled ultrasonic materials characterizationUltrasonics, 2014
- FEA of CMUTs suitable for wide gas pressure range applications2010
- Development and assessment of a new operating principle for the measurement of unsteady flow rates in high-pressure pipelinesFlow Measurement and Instrumentation, 2009
- Measurement of high-pressure natural gas flow using ultrasonic flowmetersMeasurement, 1997
- Automation of an ultrasound velocity measurement system in high-pressure liquidsMeasurement Science and Technology, 1997