Direct determination of plutonium(V) and neptunium(V) complexation by carbonate ligand with CE‐ICP‐sector field MS
- 13 May 2009
- journal article
- ce and-cec
- Published by Wiley in Electrophoresis
- Vol. 30 (10) , 1747-1755
Abstract
Direct determination of the stability constants of some pentavalent actinides (Np and Pu) with carbonate ligands was investigated by CE‐ICP‐sector field MS (SFMS). The high sensitivity of ICP‐SFMS coupled with the high separation power of CE makes it possible to determine the mobility of each species as well as the stability constants with good accuracy. A procedure for preparing pentavalent plutonium at trace level has been successfully tested enabling the study of Pu(V) complexation by CE‐ICP‐SFMS. Stability constants β1, β2 and β3 have been obtained at 25±1°C at a constant ionic strength of 0.37 M in NaClO4 for K1 and NaCl for β2 and β3. The results were extrapolated to zero ionic strength and compared with data available in the literature for Np(V). The following stability constants were obtained for a Pu(V)/CO3 system:Keywords
This publication has 16 references indexed in Scilit:
- Evidence of different stoichiometries for the limiting carbonate complexes across the lanthanide(III) series: A capillary electrophoresis‐mass spectrometry studyElectrophoresis, 2008
- Solubility and redox reactions of Pu(IV) hydrous oxide: Evidence for the formation of PuO2+x(s, hyd)Radiochimica Acta, 2007
- Challenges in modelling and optimisation of stability constants in the study of Cu–(TAPS)x–(OH)y system by polarographyTalanta, 2007
- Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry for redox speciation of plutoniumRadiochimica Acta, 2005
- Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace levelJournal of Radioanalytical and Nuclear Chemistry, 2004
- Disequilibrium effects in metal speciation by capillary electrophoresis inductively coupled plasma mass spectrometry (CE-ICP-MS); theory, simulations and experimentsElectronic supplementary information (ESI) available: Computer simulations of Sm-Cit (Animation 1, corresponding with Fig. 3), Sm-HA (Animation 2, corresponding with Fig. 4) and Sm-HA-EDTA (Animation 3) separations. See http://www.rsc.org/suppdata/an/b4/b407162j/.The Analyst, 2004
- Separation of Plutonium and Neptunium Species by Capillary Electrophoresis−Inductively Coupled Plasma-Mass Spectrometry and Application to Natural Groundwater SamplesAnalytical Chemistry, 2003
- Determination of the absolute mobility and the equivalent ionic conductivity of NpO2+ at 25 °C and at infinite dilution by capillary electrophoresis–inductively coupled plasma-mass spectrometryJournal of Chromatography A, 2003
- Coulometric titration in the study of metal ion-ligand equilibriaTalanta, 1992
- Hydrogen Ion Buffers for Biological Research*Biochemistry, 1966