Abstract
Background: The transpulmonary thermal dilution technique has been widely adopted for monitoring cardiac preload and extravascular lung water in critically ill patients. This method assumes intrathoracic blood volume (ITBV) to be a fixed proportion of global end-diastolic volume (GEDV). This study determines the relation between GEDV and ITBV under normovolemic and hypovolemic conditions and quantifies the errors in estimating ITBV. Methods: Nineteen pigs allocated to control (n = 9) and shock (n = 10) groups were studied. Shock was maintained for 60 min followed by volume resuscitation. The dual dye-thermal dilution technique was used to measure GEDV and ITBV (ITBVm) at baseline (time 0), shock phase (30 and 90 min), and after resuscitation (150 min). The regression equations estimated from paired GEDV and ITBVm measurements under normovolemic and hypovolemic conditions were used to estimate ITBV from the corresponding GEDV, and the estimation errors were quantified. A more simplified equation, used in a commercially available clinical monitor (ITBV = 1.25 x GEDV), was then used to estimate ITBV. Results: The regression equation in the control group was ITBVm = 1.21 x GEDV + 99 (r = 0.89, P < 0.0001) and in the shock group at 30 and 90 min was ITBVm = 1.45 x GEDV + 0.6 (r = 0.95, P < 0.0001). The 95% confidence interval for the y-intercept was relatively wide, ranging from 31 to 168 and -47 to 49, respectively, for the two equations. The equation estimated in the control group led to overestimation of ITBV and a significant (P < 0.05) increase in errors in the shock group at 30 and 90 min. Errors in estimating ITBV using the simplified commercial algorithm were less than 15% under normovolemic and hypovolemic conditions. Conclusions: The linear relation between GEDV and ITBV is maintained in hypovolemic shock. Even though the relation between GEDV and ITBV is influenced by circulatory volume and cardiac output, the mean errors in predicting ITBV were small and within clinically tolerable limits.Keywords
This publication has 26 references indexed in Scilit:
- Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjectsCritical Care Medicine, 2004
- Hemodynamic Monitoring by Double-Indicator Dilution Technique in Patients After Orthotopic Heart TransplantationChest, 2000
- Intrathoracic Blood Volume as an End Point in Resuscitation of the Severely Burned: An Observational Study of 24 Patients2000
- Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patientsEuropean Journal of Cardio-Thoracic Surgery, 1998
- Bedside Assessment of Intravascular Volume Status in Patients Undergoing Coronary Bypass SurgeryAnesthesiology, 1994
- Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilationIntensive Care Medicine, 1992
- Evaluation of the Portable Chest Roentgenogram for Quantitating Extravascular Lung Water in Critically Ill AdultsChest, 1985
- Comparison of Double Indicator Thermodilution Measurements of Extravascular Lung Water (EVLW) with Radiographic Estimation of Lung Water in Trauma Patients1982
- Measurement of Extravascular Lung Water in Dogs Using the Thermal-Green Dye Indicator Dilution MethodAnesthesiology, 1982
- THE MEASUREMENT OF EXTRAVASCULAR LUNG WATER BY THERMAL‐GREEN DYE INDICATOR DILUTION*Annals of the New York Academy of Sciences, 1982