Value and potential limitations of vertebral fracture assessment (VFA) compared to conventional spine radiography: experience from a fracture liaison service (FLS) and a meta-analysis
Open Access
- 25 August 2017
- journal article
- research article
- Published by Springer Nature in Osteoporosis International
- Vol. 28 (10) , 2955-2965
Abstract
Summary We evaluated the value of VFA in the identification of vertebral fractures using a retrospective study and a meta-analysis. Performance of VFA was adequate in the meta-analysis although this was not demonstrated in our centre. We recommend checking the performance of VFA tools before exclusively relying on this tool. Introduction Vertebral fractures are traditionally diagnosed using conventional radiographs of the spine. Vertebral fracture assessment (VFA) has been advocated as an alternative tool in the diagnosis of these fractures. Methods We conducted a retrospective study as well as a systematic review and a meta-analysis to evaluate the performance of VFA compared to conventional spinal radiography in patients who had sustained a fracture and thus at risk for osteoporosis. A risk of bias analysis was also performed. Results The diagnostic study included 542 patients (25% male) with fractures. The sensitivity of low-radiation VFA to detect a patient with a vertebral fracture ≥ Genant grade 2 was 0.77 and its specificity 0.80. Two hundred ninety-seven (55%) patients had ≥1 and 135(25%) ≥3 unevaluable vertebrae. The systematic review identified 16 studies including a total of 3238 subjects (19% male) with a mean age range of 45 to 74 years. Seven studies had a low risk of bias and 9 had an intermediate risk, mainly due to not consecutively including patients. The pooled sensitivity of VFA to detect a patient with a vertebral fracture ≥Genant grade 2 was 0.84 (95% CI, 0.72–0.92) and specificity 0.90 (95% CI, 0.84–0.94). Conclusions Our findings from the meta-analysis suggest an adequate performance of VFA for the detection of vertebral fractures. However, we could not demonstrate these findings in our center, especially the specificity. Our data advocate caution with exclusively relying on VFA in the assessment of vertebral fractures without identifying performance and potential limitations of the technique.Keywords
Funding Information
- Leiden University Medical Center (LUMC)
This publication has 33 references indexed in Scilit:
- European guidance for the diagnosis and management of osteoporosis in postmenopausal womenOsteoporosis International, 2012
- Vertebral fracture assessment by new dual-energy X-ray absorptiometryBone, 2012
- Comparison of Densitometric and Radiographic Vertebral Fracture Assessment Using the Algorithm-Based Qualitative (ABQ) Method in Postmenopausal Women at Low and High Risk of FractureJournal of Bone and Mineral Research, 2008
- An estimate of the worldwide prevalence and disability associated with osteoporotic fracturesOsteoporosis International, 2006
- Underdiagnosis of Vertebral Fractures Is a Worldwide Problem: The IMPACT StudyJournal of Bone and Mineral Research, 2005
- Quality of life in ambulatory postmenopausal women: the impact of reduced bone mineral density and subclinical vertebral fracturesOsteoporosis International, 2004
- Epidemiology and outcomes of osteoporotic fracturesThe Lancet, 2002
- Identification of Vertebral Deformities in Women: Comparison of Radiological Assessment and Quantitative Morphometry Using Morphometric Radiography and Morphometric X-Ray AbsorptiometryJournal of Bone and Mineral Research, 2000
- Prevalent Vertebral Deformities Predict Hip Fractures and New Vertebral Deformities but Not Wrist FracturesJournal of Bone and Mineral Research, 1999
- Vertebral fracture assessment using a semiquantitative techniqueJournal of Bone and Mineral Research, 1993