Assessing the performance of different DTI motion correction strategies in the presence of EPI distortion correction
Open Access
- 20 July 2016
- journal article
- research article
- Published by Wiley in Human Brain Mapping
- Vol. 37 (12) , 4405-4424
Abstract
Diffusion tensor imaging (DTI) is susceptible to several artifacts due to eddy currents, echo planar imaging (EPI) distortion and subject motion. While several techniques correct for individual distortion effects, no optimal combination of DTI acquisition and processing has been determined. Here, the effects of several motion correction techniques are investigated while also correcting for EPI distortion: prospective correction, using navigation; retrospective correction, using two different popular packages (FSL and TORTOISE); and the combination of both methods. Data from a pediatric group that exhibited incidental motion in varying degrees are analyzed. Comparisons are carried while implementing eddy current and EPI distortion correction. DTI parameter distributions, white matter (WM) maps and probabilistic tractography are examined. The importance of prospective correction during data acquisition is demonstrated. In contrast to some previous studies, results also show that the inclusion of retrospective processing also improved ellipsoid fits and both the sensitivity and specificity of group tractographic results, even for navigated data. Matches with anatomical WM maps are highest throughout the brain for data that have been both navigated and processed using TORTOISE. The inclusion of both prospective and retrospective motion correction with EPI distortion correction is important for DTI analysis, particularly when studying subject populations that are prone to motion. Hum Brain Mapp 37:4405–4424, 2016. © 2016 Wiley Periodicals, Inc.Keywords
Funding Information
- National Institutes of Health (R01HD071664 and R21MH096559)
This publication has 40 references indexed in Scilit:
- Improving DTI Tractography by including Diagonal Tract PropagationPLOS ONE, 2012
- Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography resultsNeuroImage, 2012
- Diffusion imaging with prospective motion correction and reacquisitionMagnetic Resonance in Medicine, 2011
- Effects of physiological noise in population analysis of diffusion tensor MRI dataNeuroImage, 2011
- Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar ImagingNeuroImage, 2010
- Assessing and minimizing the effects of noise and motion in clinical DTI at 3 THuman Brain Mapping, 2008
- Brain morphometry with multiecho MPRAGENeuroImage, 2008
- Diffusion Tensor MR Imaging and Fiber Tractography: Technical ConsiderationsAmerican Journal of Neuroradiology, 2008
- AFNI: Software for Analysis and Visualization of Functional Magnetic Resonance NeuroimagesComputers and Biomedical Research, 1996
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945