Extending the dynamic range of biomarker quantification through molecular equalization
Preprint
Abstract
Precision medicine requires highly scalable methods of multiplexed biomarker quantification that can accurately describe patient physiology. Unfortunately, contemporary molecular detection methods are generally limited to a dynamic range of sensitivity spanning just 3–4 orders of magnitude, whereas the actual physiological dynamic range of the human plasma proteome spans more than 10 orders of magnitude. Current methods rely on sample splitting and differential dilution to compensate for this mismatch, but such measures greatly limit the reproducibility and scalability that can be achieved—in particular, the effects of non-linear dilution can greatly confound the analysis of multiplexed assays. We describe here a two- pronged strategy for equalizing the signal generated by each analyte in a multiplexed panel, thereby enabling simultaneous quantification of targets spanning a wide range of concentrations. We apply our ‘EVROS’ strategy to a proximity ligation assay and demonstrate simultaneous quantification of four analytes present at concentrations spanning from low femtomolar to mid-nanomolar levels. In this initial demonstration, we achieve a dynamic range spanning seven orders of magnitude in a single 5 µl sample of undiluted human serum, highlighting the opportunity to achieve sensitive, accurate detection of diverse analytes in a highly multiplexed fashion.Keywords
All Related Versions
- Published version: Nature Communications, 14 (1), 1.
This publication has 28 references indexed in Scilit:
- Solid-phase proximity ligation assays for individual or parallel protein analyses with readout via real-time PCR or sequencingNature Protocols, 2013
- Hook Effect: A Pitfall Leading to Misdiagnosis of Hypoaldosteronism in an Infant with PseudohypoaldosteronismHormone Research in Paediatrics, 2010
- Sensitive Plasma Protein Analysis by Microparticle-based Proximity Ligation AssaysMolecular & Cellular Proteomics, 2010
- IL-18 is involved in vascular injury in end-stage renal disease patientsNephrology Dialysis Transplantation, 2008
- Sensitive protein detection via triple-binder proximity ligation assaysNature Methods, 2006
- Role of Macrophage Inhibitory Cytokine-1 in Tumorigenesis and Diagnosis of CancerCancer Research, 2006
- Contextual interactions determine whether the Drosophila homeodomain protein, Vnd, acts as a repressor or activatorNucleic Acids Research, 2005
- Triggered amplification by hybridization chain reactionProceedings of the National Academy of Sciences, 2004
- The Human Plasma ProteomeMolecular & Cellular Proteomics, 2002
- Protein detection using proximity-dependent DNA ligation assaysNature Biotechnology, 2002