A staggered 3-layer DOI PET detector using BaSO 4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability
Authors:
- 28 April 2021
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (3) , 035018
Abstract
The spatial resolution of small animal positron emission tomography (PET) scanners can be improved by the use of crystals with fine pitch and rejection of inter-crystal scattering (ICS) events, which leads to a better quantification of radiopharmaceuticals. On the other hand, depth-of-interaction (DOI) information is essential to preserve the spatial resolution at the PET field-of-view (FOV) periphery while keeping the sensitivity. In this study we proposed a novel staggered 3-layer DOI detector using BaSO 4 reflector material for an enhanced crystal identification performance as well as ICS event rejection capability over those of ESR reflector based DOI detectors. The proposed staggered 3-layer DOI detector had 3-layer staggered LYSO crystal arrays (crystal pitch = 1 mm), an acrylic light guide, and a 4 × 4 SiPM array. The 16 SiPM anode signals were read out by using a resistive network to encode the crystal position and energy information while the timing signal was extracted from the common cathode. The crystal map quality was substantially enhanced by using the BaSO 4 reflector material as compared to that of the ESR reflector due to the low optical crosstalk between the LYSO crystals. The ICS events can be rejected with BaSO 4 by using simple pulse height discrimination thanks to the light collection efficiency difference that depends on the crystal layers. As a result, the total number of events was decreased around 26% with BaSO 4 as compared to that of ESR. The overall energy resolution and coincidence timing resolution with BaSO 4 were 19.7 ± 5.6% and 591 ± 160 ps, respectively which were significantly worse than 10.9 ± 2.2% and 308 ± 23 ps values of ESR because of the relatively low light collection efficiency with BaSO 4 (1057 ± 308 ADC) compared to that of ESR (1808 ± 118 ADC). In conclusion, we found the proposed staggered 3-layer DOI detector using the BaSO 4 reflector material with ICS event rejection capability can be a cost-effective solution for realizing high resolution and highly sensitive small animal PET scanners while minimizing the complexity of the SiPM readout circuit.Keywords
This publication has 41 references indexed in Scilit:
- Bipolar analog signal multiplexing for position-sensitive PET block detectorsPhysics in Medicine & Biology, 2014
- Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readoutMedical Physics, 2014
- Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readoutPhysics in Medicine & Biology, 2013
- A practical method for depth of interaction determination in monolithic scintillator PET detectorsPhysics in Medicine & Biology, 2011
- GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapyPhysics in Medicine & Biology, 2011
- A novel, SiPM-array-based, monolithic scintillator detector for PETPhysics in Medicine & Biology, 2009
- NEMA NU 2-2007 performance measurements of the Siemens Inveon™ preclinical small animal PET systemPhysics in Medicine & Biology, 2009
- A prototype modular detector design for high resolution positron emission mammography imagingIEEE Transactions on Nuclear Science, 2003
- Design of a depth of interaction (DOI) PET detector moduleIEEE Transactions on Nuclear Science, 1998
- Simple charge division readouts for imaging scintillator arrays using a multi-channel PMTIEEE Transactions on Nuclear Science, 1996