Intraoperative Auditory Steady State Response Measurements During Vibrant Soundbridge Middle Ear Implantation in Patients With Mixed Hearing Loss
- 1 December 2010
- journal article
- audiology
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 31 (9) , 1365-1368
Abstract
Objective: To optimize intraoperatively the coupling of the floating mass transducer (FMT) of the Vibrant Soundbridge middle ear implant to the round or oval cochlear window in patients with mixed hearing loss. Study Design: Intraoperative measurement of objective hearing thresholds using auditory steady state responses (ASSRs). Setting: Radboud University Nijmegen Medical Centre, tertiary referral hospital. Patients: Four individuals with mixed hearing loss and, at least no incus, in need for a middle ear implant. Intervention: Surgical placement of the Vibrant Soundbridge. ASSR thresholds were measured intraoperatively, whereas FMT coupling to the cochlea was manipulated to find the most effective coupling of the FMT. Main Outcome Measure: Differences in ASSR thresholds between different FMT coupling options within patients. Results: With ASSR, we assessed placement of the FMT in the round window niche, loosely or tightly packed in the niche; creation of a mobile window in case of a fixed stapes footplate; and FMT position coupled to the stapes that afforded vibration in the natural vibration direction or perpendicular to it. Furthermore, test-retest variations in ASSR thresholds were studied. It was shown that differences in ASSR thresholds could be detected, while manipulating the FMT couplings, which were statistically significant. Conclusion: Intraoperative ASSR measurement is a good method to study different positions of the FMT and to determine the best position of the FMT for a patient.Keywords
This publication has 11 references indexed in Scilit:
- Coupling the Vibrant Soundbridge to Cochlea Round WindowOtology & Neurotology, 2009
- Active Middle Ear Implants in Patients Undergoing Subtotal PetrosectomyOtology & Neurotology, 2009
- The Floating Mass Transducer of the Vibrant Soundbridge Interposed Between the Stapes and Tympanic Membrane After Incus NecrosisOtology & Neurotology, 2009
- Application of the vibrant soundbridge® to unilateral osseous atresia casesThe Laryngoscope, 2008
- TORP-VibroplastyOtology & Neurotology, 2008
- New Perspectives for Middle Ear Implants: First Results in Otosclerosis With Mixed Hearing LossThe Laryngoscope, 2007
- Treatment of mixed hearing losses via implantation of a vibratory transducer on the round windowInternational Journal of Audiology, 2006
- Signal-to-Noise Ratios of the Auditory Steady-State Response from Fifty-Five EEG Derivations in AdultsJournal of the American Academy of Audiology, 2004
- Human auditory steady-state responses: Respuestas auditivas de estado estable en humanosInternational Journal of Audiology, 2003
- MASTER: a Windows program for recording multiple auditory steady-state responsesComputer Methods and Programs in Biomedicine, 2000