The Lishtot TestDrop Pro device cannot reliably indicate microbial water safety
Authors:
- Timothy PurvisTPTimothy Purvis
- Thao NguyenTNThao Nguyen
- Caitlin McHughCMCaitlin McHugh
- Siya YeolekarSYSiya Yeolekar
- Eddy DingEDEddy Ding
- Juezihan WangJWJuezihan Wang
- Kevin ZhuKZKevin Zhu
- Joe BrownJBJoe Brown
Open Access
- 18 June 2026
- journal article
- Published by Public Library of Science (PLoS) in PLOS Water
- Vol. 5 (6) , e0000442
Abstract
Low-cost, scalable tests hold great potential to increase the availability of water safety data globally, especially in resource-limited settings. We evaluated the Lishtot TestDrop Pro, a commercially available, low-cost triboelectric-based sensor marketed for real-time determination of water contamination, including microbiological safety. We prepared a total of 199 water samples by serial dilution of raw wastewater influent into deionized water to produce a range of E. coli counts from 300 per dilution plate) CFU/100 mL to evaluate the sensor. We tested these waters using the manufacturer’s instructions. We collected sensor readings using three settings on each of five devices, generating nearly 8,955 individual measurements to compare against E. coli measured via standard membrane filtration assays (EPA Method 1604), a common metric of drinking water safety. We found no statistical correlation between the sensor score and E. coli presence in water: 43% of sensor readings indicated “safe” when wastewater and E. coli was present, and 56% of samples lacking E. coli were deemed “unsafe” by the sensor when wastewater was absent. The Lishtot TestDrop Pro is not an accurate method for measuring microbiological water safety.Keywords
This publication has 23 references indexed in Scilit:
- Enhanced sensing performance of triboelectric nanosensors by solid-liquid contact electrificationNano Energy, 2020
- Capacity challenges in water quality monitoring: understanding the role of human developmentEnvironmental Monitoring and Assessment, 2020
- Where is water in the triboelectric series?Journal of Electrostatics, 2016
- In-situ tryptophan-like fluorescence: A real-time indicator of faecal contamination in drinking water suppliesWater Research, 2015
- Droplet digital PCR for simultaneous quantification of general and human-associated fecal indicators for water quality assessmentWater Research, 2015
- Evaluation of the compartment bag test for the detection of Escherichia coli in waterJournal of Microbiological Methods, 2014
- A Self‐Powered Triboelectric Nanosensor for Mercury Ion DetectionAngewandte Chemie International Edition, 2013
- Applied Logistic Regression2013
- Demonstration of the triboelectricity effect by the flow of liquid water in the insulating pipeJournal of Electrostatics, 2011
- How to average microbial densities to characterize riskWater Research, 1996