Measurement of the hydrogen-tritium-factor ratio
Authors:
- 1 April 1974
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review A
- Vol. 9 (4) , 1543-1548
Abstract
A hydrogen maser operating at fields of up to 16 G has been used as a spin-exchange detector of Zeeman transitions in the hyperfine spectra of hydrogen and tritium. The maser oscillates on the field-dependent transition which is sensitive to the state of colliding atoms. Atomic magnetic moment or -factor ratios were obtained from the measured Zeeman frequencies with the aid of the Breit-Rabi formula. Measurements were made at different values of magnetic field and an extrapolation was done to eliminate the effects of spin-exchange frequency shifts. The result is , in agreement with the theoretical predictions.
Keywords
This publication has 17 references indexed in Scilit:
- Hydrogenic Atoms in a Magnetic FieldPhysical Review A, 1971
- Hydrogen-Maser Measurements of Atomic Magnetic MomentsPhysical Review A, 1971
- Nuclear Mass Corrections to the ElectronFactorPhysical Review A, 1970
- Frequency Shifts in a Motional Field-Averaging SystemPhysical Review B, 1969
- Relativistic Treatment of the Shielding of the Electron and Proton Magnetic Dipole Moments in Atomic HydrogenPhysical Review B, 1969
- Relaxation of Optically Pumped Rb Atoms on Paraffin-Coated WallsPhysical Review B, 1966
- Hyperfine Separation of DeuteriumPhysical Review B, 1966
- Gyromagnetic Ratios of Hydrogen, Tritium, Free Electrons, andPhysical Review B, 1965
- Storage Technique for Atomic HydrogenReview of Scientific Instruments, 1962
- Resonance Experiments in Successive Oscillatory FieldsReview of Scientific Instruments, 1957