Dynamic behavior of nonlinear rolling isolation system
- 18 December 2008
- journal article
- research article
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 16 (1) , 32-54
Abstract
The linear isolator has fixed vibration frequency. When structures with these linear isolators are located near a fault, it may cause resonance and large displacement response. Hence, nonlinear isolation may avoid this situation. In this study, an eccentric nonlinear rolling isolator with a parameter, which is the eccentricity of the pin connection of the mass block (facility) to the circular isolator, is investigated. If the eccentricity is not equal to zero, the dynamic response is nonlinear rolling behavior. The equation of motion of the isolation system is derived. The frequency of the isolator increases with the eccentricity under the same initial angle. The influence of the eccentricity to the effect of isolation is scrutinized. Finally, the feasibility of the proposed isolation device is verified numerically. If the proposed isolator is designed properly, it is effective for far-field earthquake (El Centro earthquake). Even though the linearized frequency of the proposed isolator falls into the dominant frequency range of near-fault earthquake (Chi-Chi earthquake), resonance can be avoided due to nonlinearity. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 37 references indexed in Scilit:
- Nonlinear, seismic response spectra of smart sliding isolated structures with independently variable MR dampers and variable stiffness SAIVS systemSTRUCTURAL ENGINEERING AND MECHANICS, 2006
- Formulation and Implementation of a Lead-Rubber Bearing Model Including Material and Geometric Nonlinearities2006
- Experimental Study of Sliding Base-Isolated Buildings with Magnetorheological Dampers in Near-Fault EarthquakesJournal of Structural Engineering, 2005
- Foundation Isolation for Seismic Protection Using a Smooth Synthetic LinerJournal of Geotechnical and Geoenvironmental Engineering, 2004
- Performance of a Seismically Isolated Bridge under Near-Fault Earthquake Ground MotionsJournal of Structural Engineering, 2004
- Dynamic Testing of a Masonry Structure on a Passive Isolation SystemJournal of Architectural Engineering, 2004
- Passive control of the seismic rocking response of art objectsEngineering Structures, 2003
- Aseismic Roof Isolation System: Feasibility Study with 13-Story BuildingJournal of Structural Engineering, 2002
- Design of Seismic Isolated Structures1999
- DYNAMIC RESPONSE OF EQUIPMENT IN STRUCTURES WITH SLIDING SUPPORTEarthquake Engineering & Structural Dynamics, 1997