Resonant Multisensor System for High-Throughput Determinations of Solvent/Polymer Interactions
- 18 September 2004
- journal article
- Published by American Chemical Society (ACS) in Journal of Combinatorial Chemistry
- Vol. 6 (6) , 869-873
Abstract
Solvent-resistant polymers are important in numerous research, engineering, and consumer applications. To address the limitations of existing methods of evaluation of polymer solubility and solvent resistance, we developed and built a 6 × 4 array of resonant acoustic-wave sensors operating in the thickness shear mode (TSM). The application of this system makes possible analysis of nanogram quantities of polymers in small amounts of solvent and permits the simultaneous analysis of multiple samples, such as those produced in combinatorial polymerization reactions. These parallel determinations of polymer/solvent interactions eliminate errors associated with serial determinations. During the periodic exposure of the TSM crystals to polymer/solvent combinations, the mass increase of the crystal is determined, which is proportional to the amount of polymer dissolved and deposited onto the sensor from a polymer solution. We demonstrate our sensor system for reliable quantification of solubility of several types of polymers in various solvents. The high mass sensitivity of our resonant TSM sensors (10 ng), use of only a minute volume of a solvent (<2 mL), and parallel operation (matching a layout of available 24 well plates) make this system a good fit with available polymer combinatorial synthesis equipment.Keywords
This publication has 19 references indexed in Scilit:
- Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensorSensors and Actuators A: Physical, 2004
- Reaching beyond discoveryNature Materials, 2004
- Sensors in Combinatorial Polymer ResearchMacromolecular Rapid Communications, 2003
- A rapid prototyping technique for the fabrication of solvent-resistant structuresJournal of Micromechanics and Microengineering, 2003
- A Fully Integrated High-Throughput Screening Methodology for the Discovery of New Polyolefin Catalysts: Discovery of a New Class of High Temperature Single-Site Group (IV) Copolymerization CatalystsJournal of the American Chemical Society, 2003
- Chemical SensorsAnalytical Chemistry, 1998
- Solvent-resistant carbon electrodes screen printed onto plastic for use in biosensorsAnalytica Chimica Acta, 1997
- Influence of surface roughness on the quartz crystal microbalance response in a solution New configuration for QCM studiesFaraday Discussions, 1997
- Correction. Statistical Theory of Spot Overlap in Two-Dimensional SeparationsAnalytical Chemistry, 1992
- Spectral shifts in acid-base chemistry. 1. van der Waals contributions to acceptor numbersJournal of the American Chemical Society, 1990