Change in HbA1cconcentration as decision parameter for frequency of HbA1cmeasurement
- 29 May 2019
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 79 (5) , 320-324
Abstract
Hemoglobin A1c (HbA1c) is a long-term measure for glucose concentration in plasma. Since its introduction as a diabetes monitoring tool, and its more recent application as a diagnostic tool, the number of measurements of HbA1c have risen dramatically. However, HbA1c change is slow, so repeating measurements should not be done too often. We use a large, unfiltered dataset from 52,017 patients to determine the possible rate of change in HbA1c concentration. In our laboratory, the critical difference between HbA1c measurements is 8.5%. Our data show that a 1-unit HbA1c rise takes 4 weeks to occur, hence, at a HbA1c concentration around 50 mmol/mol Hgb, a critically increased HbA1c concentration cannot be determined until after 16 weeks. Conversely a critically lower HbA1c can manifest itself after 2 weeks, but after 7 weeks the dropping tendency stops. The amount of measurements that can be cancelled because they were taken sooner than 16 weeks is 23 percent.Keywords
This publication has 19 references indexed in Scilit:
- Altering a computerized laboratory test order form rationalizes ordering of laboratory tests in primary care physiciansInternational Journal of Medical Informatics, 2016
- Inappropriate Repeats of Six Common Tests in a Canadian City: A Population Cohort Study Within a Laboratory Informatics FrameworkAmerican Journal of Clinical Pathology, 2015
- Promoting improved utilization of laboratory testing through changes in an electronic medical record: experience at an academic medical centerBMC Medical Informatics and Decision Making, 2015
- Laboratory utilization improvement through a computer-aided algorithm developed with general practitionersClinical Chemistry and Laboratory Medicine (CCLM), 2015
- Managing demand for laboratory tests: a laboratory toolkitJournal of Clinical Pathology, 2012
- Glycated haemoglobin: What is the diagnostic yield at shortened testing intervals?Diabetes Research and Clinical Practice, 2011
- International Expert Committee Report on the Role of the A1C Assay in the Diagnosis of DiabetesDiabetes Care, 2009
- Elevated A1C in Adults Without a History of Diabetes in the U.S.Diabetes Care, 2009
- Translating the A1C Assay Into Estimated Average Glucose ValuesDiabetes Care, 2008
- Approved IFCC Reference Method for the Measurement of HbA1c in Human BloodClinical Chemistry and Laboratory Medicine (CCLM), 2002