Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis
Authors:
- Hyojin KimHKHyojin Kim
- Choun-Ki JooCJChoun-Ki Joo
- 1 April 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (4) , 557-561
Abstract
To evaluate the degree and direction of ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis (LASIK). Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, Seoul, Republic of Korea. The rotational position and degree were measured in 140 eyes of 70 patients with myopia or myopic astigmatism. Preoperatively, an iris image of each eye was examined using the Visx WaveScan Wavefront System (Advanced Medical Optics) iris-registration feature with the patient seated. A Visx Star S4 laser (Advanced Medical Optics) was used to measure cyclotorsion on the images before flap creation with the patient supine. The iris image was measured again after flap creation with the patient supine. The hinge of the LASIK flap was placed on the superior side and by rotating from the right to left side. The mean cyclotorsional misalignment was 2.59 degrees +/- 1.91 (SD) (right eye, 2.67 +/- 2.00 degrees; left eye, 2.51 +/- 1.98 degrees). Twenty eyes (13.0%) had cyclotorsion greater than 5 degrees. Seventy-six eyes (54.3%) had excyclotorsion. After flap creation, 107 eyes (76.4%) and 27 eyes (19.3%) rotated in the direction of identity and opposition, respectively. In eyes with cyclotorsion of identical direction, the mean increase was 1.27 +/- 0.99 degrees and 1.19 +/- 1.08 degrees in the excyclotorsion direction and incyclotorsion direction, respectively. Compensation of cyclotorsion using iris registration can be helpful in decreasing misalignment of the axis of correction and in improving the overall outcome of LASIK.Keywords
This publication has 9 references indexed in Scilit:
- Iris-Based Cyclotorsional Image Alignment Method for Wavefront RegistrationIEEE Transactions on Biomedical Engineering, 2005
- Cyclotorsional eye motion occurring between wavefront measurement and refractive surgeryJournal of Cataract & Refractive Surgery, 2004
- Maximum permissible torsional misalignment in aberration-sensing and wavefront-guided corneal ablationJournal of Cataract & Refractive Surgery, 2004
- Rotational malposition during laser in situ keratomileusisAmerican Journal of Ophthalmology, 2002
- Cyclotorsion: A possible cause of residual astigmatism in refractive surgeryJournal of Cataract & Refractive Surgery, 2002
- Effect of rotation and translation on the expected benefit of an ideal method to correct the eye’s higher-order aberrationsJournal of the Optical Society of America A, 2001
- Positioning tolerances for phase plates compensating aberrations of the human eyeApplied Optics, 2000
- Cyclotorsion in the seated and supine patientJournal of Cataract & Refractive Surgery, 1995
- Astigmatic Excimer Laser Treatment: Theoretical Effects of Axis MisalignmentEuropean journal of Implant and Refractive Surgery, 1994