Diameter and compliance of the greater saphenous vein - effect of age and nitroglycerine
- 29 March 2011
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 31 (4) , 300-306
Abstract
Objectives: The greater saphenous vein (GSV) is commonly used in autologous vein graft surgery. GSV diameter has proven to influence graft patency, and furthermore venous compliance might be of importance. The purpose of the study was to evaluate the effect of age on GSV diameter and compliance, and to evaluate the effect of nitroglycerine (NTG). Methods: The diameter and compliance of the GSV, with and without NTG, were examined with B-mode ultrasound in 12 elderly (70.3 +/- 1.2 year) and 15 young (25.1 +/- 0.6 year) men. The GSV diameter at the thigh and calf level was measured at rest, after 6 min of venous stasis (60 mmHg) and after NTG administration. Pressure-area curves during a linear venous pressure decrease were produced. Venous compliance was calculated using the quadratic regression equation (area) = beta(0) + beta(1) (cuff pressure) + beta(2) (cuff pressure)(2). Results: GVS diameter between the groups showed significant lower diameter in elderly compared to young men (P<0.05). Venous occlusion increased GSV diameter in elderly men (P<0.01) as well as young men (P<0.001). NTG increased GSV diameter in elderly men (P<0.01) with an equal trend in young men. During venous occlusion, after administration of NTG, GSV diameter increased further in both elderly (P<0.01) and young men (P<0.001). GSV compliance was decreased in elderly (beta(1), 0.037 +/- 0019, beta(2), -0.000064 +/- 00017) versus young men (beta(1), 0.128 +/- 0.013, beta(2), -0.00010 +/- 000018) [P<0.001 (beta(1)), P<0.02 (beta(2))]. Conclusions: Baseline GSV diameter as well as GSV compliance is decreased in elderly men compared to the young subjects. As reduced GSV diameter as well as reduced compliance is related to decreased graft patency, these findings might be of importance for the uses of GSV as graft material in cardiovascular bypass surgery. The clinical value has to be clarified in future studies.Keywords
This publication has 42 references indexed in Scilit:
- Venous Elastography: Validation of a Novel High‐Resolution Ultrasound Method for Measuring Vein Compliance Using Finite Element AnalysisSeminars in Dialysis, 2010
- Ultrasound assessment of popliteal vein compliance during a short deflation protocolJournal of Applied Physiology, 2008
- Effects of a 6-mo endurance-training program on venous compliance and maximal lower body negative pressure in older men and womenJournal of Applied Physiology, 2005
- Ultrasound: a reproducible method to measure conduit vein complianceJournal of Applied Physiology, 2005
- The popliteal artery, an unusual muscular artery with wall properties similar to the aorta: implications for susceptibility to aneurysm formation?Journal of Vascular Surgery, 2004
- Cardiovascular Responses to Lower Body Negative Pressure in the Elderly: Role of Reduced Leg ComplianceGerontology, 2002
- The diameter of the common femoral artery in healthy human: Influence of sex, age, and body sizeJournal of Vascular Surgery, 1999
- Decreased capacitance response with age in lower limbs of humans – a potential error in the study of cardiovascular reflexes in ageingActa Physiologica Scandinavica, 1997
- Deep venous contribution to hydrostatic blood volume change in the human legThe American Journal of Cardiology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986