Achieving a Stable High Surface Excess of Glucose Oxidase on Pristine Multiwalled Carbon Nanotubes for Glucose Quantification
- 25 March 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 2 (4) , 1740-1750
Abstract
In this study, glucose oxidase (GOx) immobilization onto ten different types of carbon modified GCEs and its direct electron transfer (DET) were investigated. A maximum amount of GOx immobilization (ΓGOx) of 2.9 nM/cm2 was achieved on the pristine multi-walled carbon nanotubes (PMWCNT) with high stability. Furthermore, the coefficient value for electron transfer (0.5) and the rate constant of 3.16 s-1 was measured from scan rate studies on PMWCNT/GOx. The derived electro-analytical parameters were superior in PMWCNT system than that of several CNT based nanocomposite materials published in the literature. The PMWCNT/GOx displayed a standard potential (E0’) of −444 mV with perfect redox peaks, and appreciable peak separation (ΔEp) value of 22 mV in neutral electrolyte medium was noted. Glucose quantification was made using the mediator, ferrocene monocarboxylic acid (FMCA) and quantification were done with dissolved oxygen (O2) reduction caused by the glucose oxidase-mediated enzymatic catalysis of glucose. Sensor calibration results revealed a broad-ranging from 0.2 to 5.8 mM with a lower limit of determination found to be 45 µM for glucose. A strong affinity between PMWCNT/GOx and glucose was assessed with Michaelis–Menten constant (2.24 mM). The proposed biosensor had excellent sensitivity and remained unaffected by the presence of other electroactive groups. This work demonstrates that pristine MWCNT can be used directly as an immobilization matrix for biosensing applications without cumbersome electrode preparation steps and the introduction of dopants.Keywords
Funding Information
- Research Councils UK (MR/P027881/1)
This publication has 54 references indexed in Scilit:
- The impact of immobilization process on the electrochemical performance, bioactivity and conformation of glucose oxidase enzymeSensors and Actuators B: Chemical, 2017
- Electrochemical sensors and biosensors based on redox polymer/carbon nanotube modified electrodes: A reviewAnalytica Chimica Acta, 2015
- A review of recent advances in nonenzymatic glucose sensorsMaterials Science and Engineering: C, 2014
- Dispersion of multi-wall carbon nanotubes in glucose oxidase: Characterization and analytical applications for glucose biosensingSensors and Actuators B: Chemical, 2012
- A Glucose Biosensor Based on Deposition of Glucose Oxidase onto Crystalline Gold Nanoparticle Modified Carbon Nanotube ElectrodeThe Journal of Physical Chemistry B, 2009
- Electrochemical Glucose BiosensorsChemical Reviews, 2007
- Glucose oxidase anode for biofuel cell based on direct electron transferElectrochemistry Communications, 2006
- Solubilization of Multiwall Carbon Nanotubes by 3‐Aminopropyltriethoxysilane Towards the Fabrication of Electrochemical Biosensors with Promoted Electron TransferElectroanalysis, 2004
- Direct electron transfer of glucose oxidase on carbon nanotubesNanotechnology, 2002
- Integration of Layered Redox Proteins and Conductive Supports for Bioelectronic ApplicationsAngewandte Chemie International Edition, 2000