Implementation, Characterization, and Evaluation of an Inexpensive Low-Power Low-Noise Infrasound Sensor Based on a Micromachined Differential Pressure Transducer and a Mechanical Filter
Authors:
Open Access
- 1 September 2012
- journal article
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 29 (9) , 1275-1284
Abstract
The implementation, characterization, and evaluation of a low-cost infrasound sensor developed at the Infrasound Laboratory at the New Mexico Institute of Mining and Technology (Infra-NMT) are described. This sensor is based on a commercial micromachined piezoresistive differential pressure transducer that uses a mechanical high-pass filter to reject low-frequency outband energy. The sensor features a low-noise, 2.02-mPa rms (0.5–2 Hz), 5.47-mPa rms (0.1–20 Hz), or 5.62-mPa rms (0.05–20 Hz), flat response between 0.01 and at least 40 Hz; inband sensitivity of 45.13 ± 0.23 μV Pa−1; and a nominal linear range from −124.5 to +124.5 Pa. Intended for outdoor applications, the influence of thermal changes in the sensor’s response has been minimized by using a thermal compensated pressure transducer powered by an ultralow drift (<5 ppm °C−1) and noise (<4μV from peak to peak) voltage reference. The sensor consumes a minimum of 24 mW and operates with voltages above 8 V while drawing 3 mA of current. The Infra-NMT specifications described above were independently verified using the infrasound test chamber at the Sandia National Laboratories’ (SNL’s) Facility for Acceptance, Calibration, and Testing (FACT), and the following procedures are for comparison calibration against traceable reference stands in voltage and pressure. Because of the intended broad frequency response of this sensor, the testing chamber was configured in a double-reference sensor scheme. A well-characterized microbarometer (with a flat-amplitude response between 0.01 and 8 Hz) and a microphone (with a flat-amplitude response above 8 Hz) were used simultaneously in this double-reference test configuration.Keywords
This publication has 23 references indexed in Scilit:
- Monotonic infrasound and Helmholtz resonance at Volcan Villarrica (Chile)Geophysical Research Letters, 2011
- THE SEISMOACOUSTIC WAVEFIELD: A NEW PARADIGM IN STUDYING GEOPHYSICAL PHENOMENAReviews of Geophysics, 2010
- Review: Semiconductor Piezoresistance for MicrosystemsProceedings of the IEEE, 2009
- Multiyear validation of the NRL‐G2S wind fields using infrasound from YasurJournal of Geophysical Research: Atmospheres, 2007
- Ambient infrasound noiseGeophysical Research Letters, 2005
- Design optimization of a piezoresistive pressure sensor considering the output signal-to-noise ratioJournal of Micromechanics and Microengineering, 2004
- Infrasonic wind-noise reduction by barriers and spatial filtersThe Journal of the Acoustical Society of America, 2003
- Interpretation and utility of infrasonic records from erupting volcanoesJournal of Volcanology and Geothermal Research, 2003
- Atmospheric InfrasoundPhysics Today, 2000
- A microbarographJournal of Scientific Instruments, 1962