Volume‐Controlled 19F MR Ventilation Imaging of Fluorinated Gas
Open Access
- 17 August 2022
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (4) , 1114-1128
Abstract
Background: 19F MRI of inhaled gas tracers has developed into a promising tool for pulmonary diagnostics. Prior to clinical use, the intersession repeatability of acquired ventilation parameters must be quantified and maximized.Purpose: To evaluate repeatability of static and dynamic 19F ventilation parameters and correlation with predicted forced expiratory volume in 1 second (FEV1%pred) with and without inspiratory volume control.Study Type: Prospective.Population: A total of 30 healthy subjects and 26 patients with chronic obstructive pulmonary disease (COPD).Field Strength/Sequence: Three‐dimensional (3D) gradient echo pulse sequence with golden‐angle stack‐of‐stars k‐space encoding at 1.5 T.Assessment: All study participants underwent 19F ventilation MRI over eight breaths with inspiratory volume control (w VC) and without inspiratory volume control (w/o VC), which was repeated within 1 week. Ventilated volume percentage (VVP), fractional ventilation (FV), and wash‐in time (WI) were computed. Lung function testing was conducted on the first visit.Statistical Tests: Correlation between imaging and FEV1%pred was measured using Pearson correlation coefficient (r). Differences in imaging parameters between first and second visit were analyzed using paired t‐test. Repeatability was quantified using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Minimum detectable effect size (MDES) was calculated with a power analysis for study size n = 30 and a power of 0.8. All hypotheses were tested with a significance level of 5% two sided.Results: Strong and moderate linear correlations with FEV1%pred for COPD patients were found in almost all imaging parameters. The ICC w VC exceeds the ICC w/o VC for all imaging parameters. CoV was significantly lower w VC for initial VVP in COPD patients, FV, CoV FV, WI and standard deviation (SD) of WI. MDES of all imaging parameters were smaller w VC.Data Conclusion: 19F gas wash‐in MRI with inspiratory volume control increases the correlation and repeatability of imaging parameters with lung function testing.Evidence Level: 2Technical Efficacy: Stage 2Keywords
Funding Information
- German Center for Lung Research
This publication has 28 references indexed in Scilit:
- Application unit for the administration of contrast gases for pulmonary magnetic resonance imaging: optimization of ventilation distribution for 3He‐MRIMagnetic Resonance in Medicine, 2014
- Pulmonary Ultrashort Echo Time19F MR Imaging with Inhaled Fluorinated Gas Mixtures in Healthy Volunteers: FeasibilityRadiology, 2013
- Physiorack: An integrated MRI safe/conditional, Gas delivery, respiratory gating, and subject monitoring solution for structural and functional assessments of pulmonary functionJournal of Magnetic Resonance Imaging, 2013
- Hyperpolarized3He and129Xe MR Imaging in Healthy Volunteers and Patients with Chronic Obstructive Pulmonary DiseaseRadiology, 2012
- Guidelines for estimating repeatabilityMethods in Ecology and Evolution, 2011
- Quantitative mapping of ventilation‐perfusion ratios in lungs by 19F MR imaging of T1 of inert fluorinated gasesMagnetic Resonance in Medicine, 2008
- Global Strategy for the Diagnosis, Management, and Prevention of Chronic Obstructive Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 2007
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Relaxation and diffusion of perfluorocarbon gas mixtures with oxygen for lung MRIJournal of Magnetic Resonance, 2006
- Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)Magnetic Resonance in Medicine, 2006