Study Objectives: To longitudinally compare sleep/wake identification and sleep parameter estimation from sleep diaries to accelerometers using different algorithms and epoch lengths in infants. Methods: Mothers and other caregivers from the Nurture study (southeastern United States, 2013–2018) reported infants’ 24-hour sleep in sleep diaries for 4 continuous days, while infants concurrently wore accelerometers on the left ankle at 3, 6, 9, and 12 months of age. We applied the Sadeh, Sadeh Infant, Cole, and Count-scaled algorithm to accelerometer data at 15 and 60 seconds epochs. For sleep/wake identification, we assessed agreement by calculating epoch-by-epoch percent agreement and kappas. We derived sleep parameters from sleep diaries and accelerometers separately and evaluated agreement using Bland–Altman plots. We estimated longitudinal trajectories of sleep parameters using marginal linear and Poisson regressions with generalized estimation equation estimation. Results: Among the 477 infants, 66.2% were black and 49.5% were female. Agreement for sleep/wake identification varied by epoch length and algorithm. Relative to sleep diaries, we observed similar nighttime sleep offset, onset, and total nighttime sleep duration from accelerometers regardless of algorithm and epoch length. However, accelerometers consistently estimated about 1 less nap per day using the 15 seconds epoch, 70 and 50 minutes’ shorter nap duration per day using the 15 and 60 seconds epoch, respectively; but accelerometers estimated over 3 times more wake after nighttime sleep onset (WASO) per night. Some consistent sleep parameter trajectories from 3 to 12 months from accelerometers and sleep diaries included fewer naps and WASOs, shorter total daytime sleep, longer total nighttime sleep, and higher nighttime sleep efficiency. Conclusions: Although there is no perfect measure of sleep in infancy, our findings suggest that a combination of accelerometer and diary may be needed to adequately measure infant sleep.Keywords
Funding Information
- National Institutes of Health (R01DK094841)
This publication has 42 references indexed in Scilit:
- Infant Attachment and Toddlers’ Sleep Assessed by Maternal Reports and Actigraphy: Different Measurement Methods Yield Different RelationsJournal of Pediatric Psychology, 2013
- Use of actigraphy for assessment in pediatric sleep researchSleep Medicine Reviews, 2012
- Algorithms for using an activity-based accelerometer for identification of infant sleep–wake states during nap studiesSleep Medicine, 2012
- Prevalence, Patterns, and Persistence of Sleep Problems in the First 3 Years of LifePediatrics, 2012
- Parental report of infant sleep behavior by electronic versus paper-and-pencil diaries, and their relationship to actigraphic sleep measurementJournal of Sleep Research, 2011
- Comparing sleep measures of infants derived from parental reports in sleep diaries and acceleration sensorsActa Paediatrica, 2011
- Cross-cultural differences in infant and toddler sleepSleep Medicine, 2010
- Algorithms for sleep–wake identification using actigraphy: a comparative study and new resultsJournal of Sleep Research, 2009
- Activity-based assessment of sleep-wake patterns during the 1st year of lifeInfant Behavior and Development, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986