Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: A pilot study
Authors:
- 29 December 2014
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (2) , 157-164
Abstract
The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three cadaver specimens total hip arthroplasty was performed bilaterally. Four different states of implant loosening were simulated. Three accelerometers were fixed at the medial condyle, the greater trochanter, and the crest of the ilium. The bone-implant compound was excited with highly standardized extracorporeal shock waves. Resonance spectra between 100 Hz and 5000 Hz were recorded. This technique permitted a good adaptation to varying soft tissue conditions. The main resonance frequency of the hip joints occurred at about 2000 Hz. The analysis of the measured spectra showed an interrelation between the state of loosening and the frequency values of the resonances. In case of a stem loosening, there were significant shifts of the resonance into the lower frequency area between 386 Hz and 847 Hz. With this novel technique the degree of stem loosening could be assessed in a soft tissue considering configuration. This study forms a first step for future establishment of a non-invasive, non-radiological and fast applicable diagnostic procedure for early detection of endoprostheses loosening before manifest presence of clinical signs.Keywords
This publication has 27 references indexed in Scilit:
- A finite element analysis of the vibrational behaviour of the intra-operatively manufactured prosthesis–femur systemMedical Engineering & Physics, 2009
- In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prosthesesJournal of Orthopaedic Surgery and Research, 2009
- Bone vibration measurement using ultrasound: Application to detection of hip prosthesis looseningMedical Engineering & Physics, 2007
- EndoprothesenlockerungenTrauma und Berufskrankheit, 2007
- How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?Clinical Biomechanics, 2003
- Accurate diagnosis of hip prosthesis loosening using a vibrational techniqueClinical Biomechanics, 2001
- A telemetry system for the detection of hip prosthesis loosening by vibration analysisSensors and Actuators A: Physical, 2000
- Vibration analysis in the detection of total hip prosthetic looseningMedical Engineering & Physics, 1996
- Loosening of total hip arthroplasty. Diagnosis by vibration analysisThe Journal of Bone and Joint Surgery. British volume, 1995
- The Differentiation of Loose and Secure Femoral Implants in Total Hip Replacement Using a Vibrational Technique: An Anatomical and Pilot Clinical StudyProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1989