A Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
Authors:
Open Access
- 2 July 2016
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 5 (4) , 10
Abstract
Purpose: We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. Methods: Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visual axis, and underwent optical biometry (Nidek AL scanner). The relative anteroposterior position of the pupillary image was expressed using the ratio between: (1) lateral photographic temporal limbus to pupil distance (“E”) and (2) lateral photographic temporal limbus to cornea distance (“Z”). In the first chronological half of patients (Correlation Series), E:Z ratio (EZR) was correlated with optical biometric ACD. The correlation equation was then used to predict ACD in the second half of patients (Prediction Series) and compared to their biometric ACD for agreement analysis. Results: A strong linear correlation was found between EZR and ACD, R = −0.91, R2 = 0.81. Bland-Altman analysis showed good agreement between predicted ACD using this method and the optical biometric ACD. The mean error was −0.013 mm (range −0.377 to 0.336 mm), standard deviation 0.166 mm. The 95% limits of agreement were ±0.33 mm. Conclusions: Lateral digital photography and EZR calculation is a novel method to quantitatively estimate ACD, requiring minimal equipment and training. Translational Relevance: EZ ratio may be employed in screening for angle closure glaucoma. It may also be helpful in outpatient medical clinic settings, where doctors need to judge the safety of topical or systemic pupil-dilating medications versus their risk of triggering acute angle closure glaucoma. Similarly, non ophthalmologists may use it to estimate the likelihood of acute angle closure glaucoma in emergency presentations.Keywords
This publication has 12 references indexed in Scilit:
- The Handan Eye Study: Comparison of Screening Methods for Primary Angle Closure Suspects in a Rural Chinese PopulationOphthalmic Epidemiology, 2014
- Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomographyBritish Journal of Ophthalmology, 2007
- Anterior Chamber Depth and the Risk of Primary Angle Closure in 2 East Asian PopulationsArchives of Ophthalmology (1950), 2005
- Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian PopulationArchives of Ophthalmology (1950), 2000
- Biometry and Primary Angle-closure Glaucoma among Chinese, White, and Black PopulationsOphthalmology, 1997
- The flashlight test and van Herick's test are poor predictors for occludable anglesAustralian and New Zealand Journal of Ophthalmology, 1996
- The anatomy of the limbusEye, 1989
- Estimation of Width of Angle of Anterior ChamberAmerican Journal of Ophthalmology, 1969
- Chamber Depth in Primary Acute GlaucomaBritish Journal of Ophthalmology, 1956
- Shallow anterior chamber in acute glaucoma; a clinical and genetic study.1953