Inertial Sensor Technology Can Capture Changes in Dynamic Balance Control during the Y Balance Test
Authors:
- William JohnstonWJWilliam Johnston
- Martin O’rEillyMOMartin O’rEilly
- Brian CaulfieldBCBrian Caulfield
Open Access
- 9 January 2018
- journal article
- Published by S. Karger AG in Digital Biomarkers
- Vol. 1 (2) , 106-117
Abstract
Introduction: The Y Balance Test (YBT) is one of the most commonly utilised clinical dynamic balance assessments. Research has demonstrated the utility of the YBT in identifying balance deficits in individuals following lower limb injury. However, quantifying dynamic balance based on reach distances alone fails to provide potentially important information related to the quality of movement control and choice of movement strategy during the reaching action. The addition of an inertial sensor to capture more detailed motion data may allow for the inexpensive, accessible quantification of dynamic balance control during the YBT reach excursions. As such, the aim of this study was to compare baseline and fatigued dynamic balance control, using reach distances and 95EV (95% ellipsoid volume), and evaluate the ability of 95EV to capture alterations in dynamic balance control, which are not detected by YBT reach distances. Methods: As part of this descriptive laboratory study, 15 healthy participants completed repeated YBTs at 20, 10, and 0 min prior to and following a modified 60-s Wingate test that was used to introduce a short-term reduction in dynamic balance capability. Dynamic balance was assessed using the standard normalised reach distance method, while dynamic balance control during the reach attempts was simultaneously measured by means of the 95EV derived from an inertial sensor, worn at the level of the 4th lumbar vertebra. Results: Intraclass correlation coefficients for the inertial sensor-derived measures ranged from 0.76 to 0.92, demonstrating strong intrasession test-retest reliability. Statistically significant alterations (p < 0.05) in both reach distance and the inertial sensor-derived 95EV measure were observed immediately post-fatigue. However, reach distance deficits returned to baseline levels within 10 min, while 95EV remained significantly increased (p < 0.05) beyond 20 min for all 3 reach distances. Conclusion: These findings demonstrate the ability of an inertial sensor-derived measure to quantify alterations in dynamic balance control, which are not captured by traditional reach distances alone. This suggests that the addition of an inertial sensor to the YBT may provide clinicians and researchers with an accessible means to capture subtle alterations in motor function in the clinical setting.Keywords
This publication has 30 references indexed in Scilit:
- Investigating the effects of maximal anaerobic fatigue on dynamic postural control using the Y-Balance TestJournal of Science and Medicine in Sport, 2018
- Wearable sensing and mobile devices: the future of post-concussion monitoring?Concussion, 2017
- The reliability of the quantitative timed up and go test (QTUG) measured over five consecutive days under single and dual-task conditions in community dwelling older adultsGait & Posture, 2016
- Association of Y Balance Test Reach Asymmetry and Injury in Division I AthletesMedicine & Science in Sports & Exercise, 2015
- The Effects of Gender and Fatigue on Dynamic Postural ControlJournal of Sport Rehabilitation, 2009
- Star Excursion Balance Test as a Predictor of Lower Extremity Injury in High School Basketball PlayersJournal of Orthopaedic & Sports Physical Therapy, 2006
- Effect of lower-extremity muscle fatigue on postural controlArchives of Physical Medicine and Rehabilitation, 2004
- Can Aerobic and Anaerobic Power be Measured in a 60-Second Maximal Test?2003
- Contribution of energy systems during a Wingate power test.British Journal of Sports Medicine, 1991
- DEVELOPING CRITERIA FOR ESTABLISHING INTERRATER RELIABILITY OF SPECIFIC ITEMS - APPLICATIONS TO ASSESSMENT OF ADAPTIVE-BEHAVIOR1981