Biomechanical Evaluation of Sagittal Split Ramus Osteotomy Fixation Techniques in Mandibular Setback
Open Access
- 26 April 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3031
Abstract
The objective of this study was to evaluate and compare the biomechanical behavior of internal fixation techniques in bilateral sagittal split ramus osteotomies (BSSROs) for mandibular setback. Artificial polyurethane mandibles were used in this study. The distal segment of the mandible was repositioned in an 8-mm setback position. All mandibles were divided into three groups: Group 1 had a straight plate with a four-hole monocortical fixation, Group 2 had a curved plate with a four-hole monocortical fixation, and Group 3 had a three–inverted L-type bicortical screw fixation. Vertical loads were applied on the incisal edge by a material testing system. The resistance force at 1, 3, 5, and 10 mm of displacement was analyzed. From the experimental results, Group 1 showed significantly lower results than Groups 2 and 3. No significant difference was observed between Groups 2 and 3 at 1, 3, and 5 mm of displacement. However, at 10 mm of displacement, the resistance force of Group 3 was greater than that of Group 2. For BSSROs, this study concluded that curved plate fixation exhibited the same rigidity as the inverted-L bicortical screw fixation did at ≤5 mm displacement.Keywords
Funding Information
- China Medical University, Taiwan (CMU108-S-01)
This publication has 25 references indexed in Scilit:
- An In Vitro Evaluation of Rigid Internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Setback SurgeryJournal of Oral and Maxillofacial Surgery, 2012
- Comparison of stability of 2.0mm standard and 2.0mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandiblesBritish Journal of Oral and Maxillofacial Surgery, 2011
- Stability of osteosynthesis with bicortical screws placed in a triangular shape in mandibular sagittal split 5mm advancement osteotomy: Biomechanical testsBritish Journal of Oral and Maxillofacial Surgery, 2010
- In Vitro Biomechanical Evaluation of the Use of Conventional and Locking Miniplate/Screw Systems for Sagittal Split Ramus OsteotomyJournal of Oral and Maxillofacial Surgery, 2010
- Orthognathic Surgery and a Tale of How Three Procedures Came to Be: A Letter to the Next Generations of SurgeonsClinics in Plastic Surgery, 2007
- In vitro comparison of biomechanical characteristics of sagittal split osteotomy fixation techniquesInternational Journal of Oral and Maxillofacial Surgery, 2006
- A Biomechanical Evaluation of Bilateral Sagittal Ramus Osteotomy Fixation TechniquesJournal of Oral and Maxillofacial Surgery, 2005
- Neurosensory disturbance after sagittal split and intraoral vertical ramus osteotomy: as reported in questionnaires and patients’ recordsInternational Journal of Oral and Maxillofacial Surgery, 2005
- Mandibular setback by sagittal split ramus osteotomy: A 12-year follow-upActa Odontologica Scandinavica, 2005
- Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomyBritish Journal of Oral and Maxillofacial Surgery, 2004