Introduction Hydrogen production from water electrolysis possesses significant potential, particularly for long-term renewable energy storage systems. Therefore, utilizing seawater instead of fresh water may be crucial, especially in coastal and offshore applications. However, it poses the risk of poisoning electrolyzers during failures or by supplying trace amounts of salt through insufficiently treated water. This risk is especially critical for solid oxide cells (SOC), which are known to be vulnerable to poisoning associated with chlorine and sulfur - both of which are present in seawater. If salts infiltrate the SOC stacks, they can significantly accelerate the degradation of stack materials, including the cells themselves. Therefore, this study serves as a preliminary investigation, analyzing the impact of seawater components on the performance and durability of solid oxide cells' materials. Methods and materials: The research focused on the microstructural and electrochemical evaluation of 5 cm x 5 cm SOC cells impregnated with salt water with additional microstructural and chemical analysis (e.g., SEM-EDS, XRD) of the glass sealing and cells. The SOCs electrochemical analysis includes linear voltammetry, long-term galvanostatic measurements, and electrochemical impedance spectroscopy. The samples were impregnated with two saltwater solutions: one containing NaCl and another simulating seawater, containing Na, Cl, Mg, Ca, K, S, B, and Sr, among others. To simulate various aquatic environments, different salinity levels were assumed. Results: Analysis of electrochemical results for the cell exposed to salt performed 0.47 A cm -2 in SOFC mode at 0.7 V and 700°C when fueled with 100 Nml min -1 N 2 and 100 Nml min -1 H 2 . In SOEC mode at 1.4 V, 700°C, and fuel electrode gas composition 180 g min -1 H 2 O and 20 Nml min -1 H 2 , the cell was loaded with 0.66 A cm -2 . For both SOFC and SOEC modes under the same conditions, the current density was more than 10% lower than in the reference cell measurements, where no salt contamination was introduced. Additionally, substantial degradation has been noted after 180 hours of characterization. A microstructural post-mortem examination revealed deterioration of the cell’s microstructure. (Fig.1) Post-mortem analysis and further experiments showed that salt components accumulate within the cell microstructure and react with the barium glass-based sealant. This reaction has a twofold effect: it reduces cell performance and causes leakage, also influencing the measured performance. The latter was confirmed by burnouts on the cell housing. These phenomena demonstrate the vulnerability of SOCs to salt contamination, emphasizing the necessity for protective measures. (Fig. 2) Acknowledgments This study received funding from the European Union - Next-GenerationEU - National Recovery and Resilience Plan (NRRP) – MISSION 4 COMPONENT 2, INVESTMENT N. 1.1, CALL PRIN 2022 PNRR D.D. 1409 14-09-2022 – “POSEIDON - Photo-driven Optimal Seawater Electrolysis for energy-IslanDs OperatioN” P2022ER7KM –PE8, CUP I53D23006440001 Figure 1 Figure 2