Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study
Open Access
- 24 July 2025
- journal article
- Published by SAGE Publications in Journal of Neonatal-Perinatal Medicine
- Vol. 18 (5) , 456-466
Abstract
Background: Prior studies on the reliability of targeted neonatal echocardiography (TNE) among extremely low gestational age neonates (ELGANs) with a patent ductus arteriosus (PDA) have been limited to evaluation of pre-defined images by a small set of study observers. The objective of this study was to investigate the interobserver reliability of comprehensive echocardiography measures of PDA size/shunt volume and ventricular performance among TNE-neonatologists in a large national network. Methods: We conducted a prospective observational study. TNEs performed for the evaluation of PDA among ELGANs were analyzed by TNE-neonatologists from the Canadian TNE Consortium. Analyses were conducted via an interactive videoconferencing platform offering full remote control to the review software. Reliability for continuous measures was evaluated using the intraclass correlation coefficient (ICC) and coefficient of variation. The kappa statistic was used to evaluate the interobserver reliability of categorical parameters. Results: Reliability was excellent among indices of PDA size and gradient (ICC≥0.91) and good-to-excellent among most indices of left ventricular (LV) size and output (ICC≥0.79, except for LV end-systolic volume and left atrium to aortic root ratio). There was substantial to near-complete agreement on PDA shunt direction and diastolic flow abnormalities in the abdominal aorta and systemic arteries (kappa ≥0.78). However, reliability for measures of LV systolic and diastolic performance was variable with ICC range 0.21–0.95, though with low coefficient of variation (<15%). Conclusions: Interobserver reliability for most TNE measures of PDA size, gradient, shunt volume, and LV dimensions and function is good-to-excellent, supporting the validity of incorporating these indices in prospective multicenter research.Keywords
Funding Information
- Canadian Institutes for Health Research (451941)
This publication has 34 references indexed in Scilit:
- Machine Learning-Enabled Fully Automated Assessment of Left Ventricular Volume, Ejection Fraction and Strain: Experience in Pediatric and Young Adult EchocardiographyPediatric Cardiology, 2022
- Repeatability of PDA diameter measurements on echocardiographyEuropean Journal of Pediatrics, 2021
- Left ventricular diastolic function influences right ventricular — Pulmonary vascular coupling in premature infantsEarly Human Development, 2019
- Agreement and reliability of the velocity time integral method and the method of disks to determine stroke volume in preterm infantsEarly Human Development, 2018
- Diagnosis, Evaluation, and Management of Patent Ductus Arteriosus in Preterm NeonatesJAMA Pediatrics, 2015
- Longitudinal Systolic Left Ventricular Function in Preterm and Term Neonates: Reference Values of the Mitral Annular Plane Systolic Excursion (MAPSE) and Calculation of z-ScoresPediatric Cardiology, 2014
- Sample size formulas for estimating intraclass correlation coefficients with precision and assuranceStatistics in Medicine, 2012
- Targeted Neonatal Echocardiography in the Neonatal Intensive Care Unit: Practice Guidelines and Recommendations for TrainingJournal of the American Society of Echocardiography, 2011
- Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variablesUltrasound in Obstetrics & Gynecology, 2008
- Sample size and optimal designs for reliability studiesStatistics in Medicine, 1998