Simultaneous Determination of Caffeine and Theophylline in Human Plasma with a Weak Cation Monolithic SPE‐column
- 1 August 2010
- journal article
- research article
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 28 (8) , 1463-1468
Abstract
A simple reversed‐phase high performance liquid chromatography (RP‐HPLC) method was developed to determine the level of caffeine and theophylline in human plasma samples. The sample clean‐up step involved the on‐line solid‐phase extraction (SPE) of the analytes from plasma samples into a weak cation monolithic column using a column switching system. Separation was performed on a C18 column (5 µm, 150 mm×4.6 mm) with ultraviolet detection at 274 nm. The mobile phase consisted of methanol‐water (32/68, V/V) under isocratic conditions at a flow rate of 0.6 mL·min−1. The measured concentration of caffeine and theophylline showed a good linear relationship over the concentrations range, 0.1–80.0 µg·mL−1. The absolute recoveries ranged from 77.10% to 85.39%, and the inter‐day and intra‐day relative standard deviations (RSD) were all less than 5%. This method avoids a tedious pretreatment and provides an economic, repeatable and effective method for assaying trace drugs in biological samples.Keywords
This publication has 24 references indexed in Scilit:
- Determination of nicardipine and amlodipine in human plasma using on-line solid-phase extraction with a monolithic weak cation-exchange columnTalanta, 2009
- Determination of fentanyl in biological and water samples using single-drop liquid–liquid–liquid microextraction coupled with high-performance liquid chromatographyAnalytica Chimica Acta, 2008
- Automated on-line column-switching HPLC-MS/MS method with peak focusing for measuring parabens, triclosan, and other environmental phenols in human milkAnalytica Chimica Acta, 2008
- Preparation and characterization of novel poly(vinyl ester resin) monolithsMicroporous and Mesoporous Materials, 2007
- Sensitive determination of ultra-trace nitric oxide in blood using derivatization-polymer monolith microextraction coupled with reversed-phase high-performance liquid chromatographyAnalytica Chimica Acta, 2007
- Anion-exchange chromatography using short monolithic columns as a complementary technique for human serum albumin depletion prior to human plasma proteome analysisJournal of Pharmaceutical and Biomedical Analysis, 2007
- Determination of low-aliphatic aldehyde derivatizatives in human saliva using polymer monolith microextraction coupled to high-performance liquid chromatographyAnalytica Chimica Acta, 2006
- Enantiomeric separation of organophosphorus pesticides by capillary electrophoresisAnalytica Chimica Acta, 2005
- Development of a rapid HPLC method for determination of famotidine in human plasma using a monolithic columnJournal of Pharmaceutical and Biomedical Analysis, 2005
- Fast high-performance liquid chromatographic analysis of mianserin and its metabolites in human plasma using monolithic silica column and solid phase extractionAnalytica Chimica Acta, 2004