An in vitro demonstration of a passive, acoustic metamaterial as a temperature sensor with mK resolution for implantable applications
Open Access
- 17 January 2024
- journal article
- research article
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-14
Abstract
Wireless medical sensors typically utilize electromagnetic coupling or ultrasound for energy transfer and sensor interrogation. Energy transfer and management is a complex aspect that often limits the applicability of implantable sensor systems. In this work, we report a new passive temperature sensing scheme based on an acoustic metamaterial made of silicon embedded in a polydimethylsiloxane matrix. Compared to other approaches, this concept is implemented without additional electrical components in situ or the need for a customized receiving unit. A standard ultrasonic transducer is used for this demonstration to directly excite and collect the reflected signal. The metamaterial resonates at a frequency close to a typical medical value (5 MHz) and exhibits a high-quality factor. Combining the design features of the metamaterial with the high-temperature sensitivity of the polydimethylsiloxane matrix, we achieve a temperature resolution of 30 mK. This value is below the current standard resolution required in infrared thermometry for monitoring postoperative complications (0.1 K). We fabricated, simulated, in vitro tested, and compared three acoustic sensor designs in the 29–43 °C (~302–316 K) temperature range. With this concept, we demonstrate how our passive metamaterial sensor can open the way toward new zero-power smart medical implant concepts based on acoustic interrogation.Keywords
This publication has 57 references indexed in Scilit:
- Measurement of the temperature coefficient of Young's modulus of single crystal silicon and 3C silicon carbide below 273 K using micro-cantileversSensors and Actuators A: Physical, 2013
- Value of digital telethermography for the diagnosis of septic knee prosthesis: a prospective cohort studyBMC Musculoskeletal Disorders, 2013
- Critical factors in cut-out complication after gamma nail treatment of proximal femoral fracturesBMC Musculoskeletal Disorders, 2013
- Healing of surgical site after total hip and knee replacements show similar telethermographic patternsJournal of Orthopaedics and Traumatology, 2011
- Scattering Theory Derivation of a 3D Acoustic Cloaking ShellPhysical Review Letters, 2008
- Prosthetic-Joint InfectionsThe New England journal of medicine, 2004
- Medical ultrasound imagingPhysics Education, 2001
- Optical In-Fiber Bragg Grating Sensor Systems for Medical ApplicationsJournal of Biomedical Optics, 1998
- Appearance of septic hip prostheses on plain radiographs.American Journal of Roentgenology, 1994
- The Velocity of Sound through Tissues and the Acoustic Impedance of TissuesThe Journal of the Acoustical Society of America, 1950