Influence of steel implant surface microtopography on soft and hard tissue integration
- 21 March 2017
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (2) , 705-715
Abstract
After implantation of an internal fracture fixation device, blood contacts the surface, followed by protein adsorption, resulting in either soft‐tissue adhesion or matrix adhesion and mineralization. Without protein adsorption and cell adhesion under the presence of micro‐motion, fibrous capsule formation can occur, often surrounding a liquid filled void at the implant–tissue interface. Clinically, fibrous capsule formation is more prevalent with electropolished stainless steel (EPSS) plates than with current commercially pure titanium (cpTi) plates. We hypothesize that this is due to lack of micro‐discontinuities on the standard EPSS plates. To test our hypothesis, four EPSS experimental surfaces with varying microtopographies were produced and characterized for morphology using the scanning electron microscope, quantitative roughness analysis using laser profilometry and chemical analysis using X‐ray photoelectron spectroscopy. Clinically used EPSS (smooth) and cpTi (microrough) were included as controls. Six plates of each type were randomly implanted, one on both the left and right intact tibia of 18 white New Zealand rabbits for 12 weeks, to allow for a surface interface study. The results demonstrate that the micro‐discontinuities on the upper surface of internal steel fixation plates reduced the presence of liquid filled voids within soft‐tissue capsules. The micro‐discontinuities on the plate under‐surface increased bony integration without the presence of fibrous tissue interface. These results support the hypothesis that the fibrous capsule and the liquid filled void formation occurs mainly due to lack of micro‐discontinuities on the polished smooth steel plates and that bony integration is increased to surfaces with higher amounts of micro‐discontinuities. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 705–715, 2018.Keywords
This publication has 42 references indexed in Scilit:
- In vivo evaluation of defined polished titanium surfaces to prevent soft tissue adhesionJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2012
- The Epidemiology of Upper Extremity Injuries Presenting to the Emergency Department in the United StatesHAND, 2011
- The Cellular Biology of Flexor Tendon Adhesion FormationThe American Journal of Pathology, 2009
- An in vivo evaluation of the biocompatibility of anodic plasma chemical (APC) treatment of titanium with calcium phosphateJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Effect of surface topography on removal of cortical bone screws in a novel sheep modelJournal of Orthopaedic Research, 2008
- Prevention of peritendinous adhesions using a hyaluronan‐derived hydrogel film following partial‐thickness flexor tendon injuryJournal of Orthopaedic Research, 2007
- Microtopography of metal surfaces influence fibroblast growth by modifying cell shape, cytoskeleton, and adhesionJournal of Orthopaedic Research, 2007
- Human fibroblast reactions to standard and electropolished titanium and Ti–6Al–7Nb, and electropolished stainless steelJournal of Biomedical Materials Research Part A, 2005
- The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture modelThe Journal of Hand Surgery, 2005
- Fibrin sealant in prevention of flexor tendon adhesions: An experimental study in the rabbitThe Journal of Hand Surgery, 1993