Electrical treeing behaviours in cross‐linked polyethylene cables after thermal ageing
Authors:
Open Access
- 30 December 2022
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (4) , 749-759
Abstract
Long‐term thermal ageing might have impacts on the physicochemical properties of cross‐linked polyethene (XLPE) cables, thereby influencing their electrical behaviours, such as electrical treeing initiation and growth. The main objective of this work is to report the effects of thermal ageing on the electrical treeing behaviours (initiation and growth) in XLPE cable insulation. For this purpose, the electrical treeing initiation and growth test were performed in accelerated thermal samples. In addition, Differential Scanning Calorimetry and Fourier Transform Infrared Spectroscopy were utilised to investigate corresponding changes in the microstructures of materials. In addition, a correlation was established between electrical treeing behaviours and physicochemical properties during the thermal ageing process. Test results indicate that the thermal ageing process should be divided into three phases, and the re‐crystallisation reaction is considered the primary reason for the increase of average electrical tree initiation voltage (AETIV). Furthermore, the thermal ageing index X c is correlated to AETIV and the propagation rate of the electrical tree. As equivalent relationships have been established between the relative decrease value w of indexes AETIV, the propagating rate and X c , this method can be employed to predict the changing pattern of electrical treeing initiation voltage and the propagating rate in future research.Keywords
This publication has 21 references indexed in Scilit:
- Relationship between space charge behavior and trap energy density distribution: A simultaneous measurementIEEE Transactions on Dielectrics and Electrical Insulation, 2019
- Accelerated inhomogeneous degradation of XLPE insulation caused by copper-rich impurities at elevated temperatureIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- On the conducting and non-conducting electrical trees in XLPE cable insulation specimensIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Electrical treeing behavior at high temperature in XLPE cable insulation samplesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Degradation distribution in insulation materials of cables by accelerated thermal and radiation ageingIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Morphology of electrical trees in silicon rubberJournal of Electrostatics, 2013
- Influence of frequency on electrical tree initiation in high-density polyethylene2008
- Comparison of XLPE Cable Peelings with Different Electro-Thermal Histories using Endurance Test and Residual Charge Methods2006
- Ageing and reliability testing and monitoring of power cables: diagnosis for insulation systems: the ARTEMIS programIEEE Electrical Insulation Magazine, 1999
- A study of treeing phenomena in the development of insulation for 500 kV XLPE cablesIEEE Transactions on Dielectrics and Electrical Insulation, 1998