Development and Validation of a Simple, Sensitive, Selective and Stability-Indicating RP-UPLC Method for the Quantitative Determination of Ritonavir and Its Related Compounds
Open Access
- 3 September 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 53 (5) , 662-675
Abstract
A simple, sensitive, selective and reproducible stability-indicating ultra-performance liquid chromatographic method was developed for the quantitative determination of degradation products and process-related impurities of Ritonavir in a pharmaceutical dosage form. Chromatographic separation was achieved on a polar embedded Waters Acquity BEH Shield RP18 (100 × 2.1 mm, 1.7 μm) column thermostated at 50°C under gradient elution by using a binary mixture of potassium dihydrogen phosphate (0.01 M, pH 3.5) and acetonitrile at a flow rate of 0.5 mL/min. Chromatogram was monitored at 240 nm using a photodiode array detector. The drug and its related impurities are eluted within 20 min. To prove the stability-indicating power of the method, the drug was subjected to hydrolytic (acid, alkaline and water), oxidative, photolytic and thermal stress conditions. The unknown degradants were identified by the LC–MS-MS method, which revealed protonated molecular ion peaks [M + H]+ at m/z 551.40 for hydrolytic degradants, and m/z 737.60 and m/z 753.40 for photolytic degradants. A plausible mechanism for the formation of degradation and process impurities was proposed. The performance of the method was validated according to the International Conference on Harmonization guidelines.Keywords
This publication has 13 references indexed in Scilit:
- LC–MS/MS studies of ritonavir and its forced degradation productsJournal of Pharmaceutical and Biomedical Analysis, 2010
- Evaluation of an International Pharmacopoeia method for the analysis of ritonavir by liquid chromatographyJournal of Pharmaceutical and Biomedical Analysis, 2008
- LC Method for Studies on the Stability of Lopinavir and Ritonavir in Soft Gelatin CapsulesChromatographia, 2006
- Determination of saquinavir and ritonavir in human plasma by reversed-phase high-performance liquid chromatography and the analytical error functionJournal of Pharmaceutical and Biomedical Analysis, 2004
- A Simple HPLC Method for Simultaneous Determination of Lopinavir, Ritonavir and EfavirenzChemical and Pharmaceutical Bulletin, 2003
- Simple and rapid high-performance liquid chromatographic method for nelfinavir, M8 nelfinavir metabolite, ritonavir and saquinavir assay in plasmaJournal of Chromatography B, 2002
- Quantification of plasma and intracellular levels of the HIV protease inhibitor ritonavir by competitive ELISAJournal of Immunological Methods, 2002
- Simultaneous determination of the HIV-protease inhibitors indinavir, amprenavir, ritonavir, saquinavir and nelfinavir in human plasma by reversed-phase high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 2001
- Simultaneous determination of the HIV protease inhibitors indinavir, amprenavir, saquinavir, ritonavir, nelfinavir and the non-nucleoside reverse transcriptase inhibitor efavirenz by high-performance liquid chromatography after solid-phase extractionJournal of Chromatography B: Biomedical Sciences and Applications, 2000
- Analysis of ritonavir in plasma/serum and tissues by high-performance liquid chromatographyJournal of Pharmacological and Toxicological Methods, 1998