Abstract
System-level wearable electronics require to be flexible to ensure conformal contact with the skin, but they also need to integrate rigid and bulky functional components to achieve system-level functionality. As one of integration methods, folding integration offers simplified processing and enhanced functionality through rigid-soft region separation, but so far, it has mainly been applied to modality of electrical sensing and stimulation. This paper introduces a vialess heterogeneous skin patch with multi modalities that separates the soft region and strain-robust region through folded structure. Our system includes electrical and optical modalities for hemodynamic and cardiovascular monitoring, and a force-electrically driven micropump for drug delivery. Each modality is demonstrated through on-demand drug delivery, flexible waveguide-based PPG monitoring, and ECG and body movement monitoring. Wireless data transmission and real-time measurement validate the feedback operation for multi-modalities. This engineered closed-loop platform offers the possibility for broad applications, including cardiovascular monitoring and chronic disease management.Keywords
Funding Information
- National Research Foundation of Korea (RS-2023-00234581, RS-2024-00460364)
This publication has 60 references indexed in Scilit:
- Stretch-Triggered Drug Delivery from Wearable Elastomer Films Containing Therapeutic DepotsACS Nano, 2015
- Wireless Optofluidic Systems for Programmable In Vivo Pharmacology and OptogeneticsCell, 2015
- Microneedle-array patches loaded with hypoxia-sensitive vesicles provide fast glucose-responsive insulin deliveryProceedings of the National Academy of Sciences of the United States of America, 2015
- Multifunctional wearable devices for diagnosis and therapy of movement disordersNature Nanotechnology, 2014
- Microneedle-assisted delivery of verapamil hydrochloride and amlodipine besylateEuropean Journal of Pharmaceutics and Biopharmaceutics, 2014
- Silk‐Molded Flexible, Ultrasensitive, and Highly Stable Electronic Skin for Monitoring Human Physiological SignalsAdvanced Materials, 2013
- Tears of Venom: Hydrodynamics of Reptilian EnvenomationPhysical Review Letters, 2011
- Monitoring technology for the elderly patientExpert Review of Medical Devices, 2007
- Pulse transit time: an appraisal of potential clinical applicationsThorax, 1999
- Δ9-Tetrahydrocannabinol: EEG changes, bradycardia and hypothermia in the rhesus monkeyBrain Research Bulletin, 1987