Tibial Intraosseous Insertion in Pediatric Emergency Care: A Review Based upon Postmortem Computed Tomography
- 7 January 2020
- journal article
- review article
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 24 (5) , 665-671
Abstract
Objective: The proximal tibia is a recommended and commonly used site for pediatric emergency intraosseous vascular access (IO). During forensic whole body postmortem computed tomography (PMCT), we evaluated accuracy of emergency placement of tibial IO access. Methods: We conducted a retrospective review of 92 state medical examiner cases to assess presence and placement of tibial IO needles. Insertions were classified as successful (needle tip in the medullary portion of the bone) or unsuccessful (all other non-medullary placements) based upon position of the needle tip. Medical records were reviewed for patient age, equipment, and where an insertion was attempted, as well as if IO placement occurred in a prehospital or hospital environment. Results: Thirty-one cases with 42 tibial devices (aged 3 weeks to 16 years, median 4 months) were identified. In 25 insertions (60%), the needle tip was in satisfactory position. In 17 placements (40%), needle tip was unsatisfactory and included tibia perforation (6), tip embedded in the cortex (6), and needle missed the bone (5). In patients older than 6 months, all six placements of a 15-mm needle were successful. In infants age 6 months or younger, 14 placements (56%) were successful and 11 (44%) unsuccessful. The 25-mm IO needle was successfully placed in five of six children older than 6 months. In infants age 6 months or younger, the 25-mm needle was unsuccessfully placed in five of five attempts. Conclusion: In infants 6 months of age or younger, tibial IO needle insertion had a 53% failure rate (non-medullary placement). Failures occur during both prehospital and emergency department care. In infants age 6 months or younger, use of a 25-mm needle should be avoided. Procedures for IO insertion in infants age 6 months or younger should be reviewed and modification considered.Keywords
This publication has 18 references indexed in Scilit:
- EZ-IO® intraosseous device implementation in German Helicopter Emergency Medical ServiceResuscitation, 2015
- Intraosseous Access EZ-IO in a Prehospital Emergency ServiceJournal of Emergency Nursing, 2013
- EZ-IO® intraosseous device implementation in a pre-hospital emergency service: A prospective study and review of the literatureResuscitation, 2013
- Intraosseous Access in the Prehospital Setting: Literature ReviewPrehospital and Disaster Medicine, 2012
- Intraosseous vascular access: A reviewTrauma, 2012
- Semiautomatic Intraosseous Devices in Pediatric Prehospital CarePrehospital Emergency Care, 2011
- Intraosseous vascular access in adults using the EZ-IO in an emergency departmentInternational Journal of Emergency Medicine, 2009
- Use of the Pediatric EZ-IO Needle by Emergency Medical Services ProvidersPediatric Emergency Care, 2009
- Powered Intraosseous Insertion Provides Safe and Effective Vascular Access for Pediatric Emergency PatientsPediatric Emergency Care, 2008
- Intraosseous infusion: An alternative route of pediatric intravascular accessAnnals of Emergency Medicine, 1985