Single-Chamber Leadless Cardiac Pacemaker in Patients Without Atrial Fibrillation: Findings From Campania Leadless Registry
Authors:
Open Access
- 14 January 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8, 781335
Abstract
Introduction: Little is known about the clinical performance of single-chamber leadless pacemaker (LLPM) in patients without atrial fibrillation (AF) as pacing indication. The aim of this study was to describe the clinical characteristics of patients who underwent single chamber LLPM implantation at three tertiary referral centers and to compare the safety and effectiveness of the single-chamber LLPM among patients with or without AF.Materials and Methods: All the consecutive patients who underwent LLPM implantation at three referral centers were analyzed. The indications to LLPM in a real-world setting were described. The study population was divided into two groups according to AF as pacing indication. We assessed the procedure-related complications; moreover, we compared syncope, cardiac hospitalization, pacemaker syndrome, and all-cause death recurrence during the follow-up between patients with and without AF as pacing indication.Results: A total of 140 consecutive patients (mean age, 76.7 ± 11.24 years, men 64.3%) were included in the study. The indication to implantation of LLPM was permanent AF with slow ventricular response (n: 67; 47.8%), sinus node dysfunction (n: 25; 17.8%), third atrioventricular block (AVB) (n: 20; 14.2%), second-degree AVB (n: 18; 12.8%), and first degree AVB (n: 10; 7.1%). A total of 7 patients (5%) experienced perioperative complications with no differences between the AF vs. non-AF groups. During a mean follow-up of 606.5 ± 265.9 days, 10 patients (7.7%) died and 7 patients (5.4%) were reported for cardiac hospitalization; 5 patients (3.8%) experienced syncope; no patients showed pacemaker syndrome. No significant differences in the clinical events between the groups were shown. The Kaplan–Meier analysis for the combined endpoints did not show significant differences between the AF and non-AF groups [hazard ratio (HR): 0.94, 95% CI: 0.41–2.16; p = 0.88].Conclusion: Our real-world data suggest that LLPM may be considered a safe and reasonable treatment in patients without AF in need of pacing. Further studies are needed to confirm these preliminary results.Keywords
This publication has 15 references indexed in Scilit:
- 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm SocietyCirculation, 2019
- To retrieve, or not to retrieve: System revisions with the Micra transcatheter pacemakerHeart Rhythm, 2017
- A leadless pacemaker in the real-world setting: The Micra Transcatheter Pacing System Post-Approval RegistryHeart Rhythm, 2017
- Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing StudyHeart Rhythm, 2017
- A Leadless Intracardiac Transcatheter Pacing SystemNew England Journal of Medicine, 2016
- Management of Cardiovascular Implantable Electronic Devices Infections in High-Risk PatientsArrhythmia and Electrophysiology Review, 2015
- Risk factors for infection of implantable cardiac devices: data from a registry of 2496 patientsEP Europace, 2012
- Single-Chamber versus Dual-Chamber Pacing for High-Grade Atrioventricular BlockNew England Journal of Medicine, 2005
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node DysfunctionThe New England journal of medicine, 2002