Abstract
This paper proposes and describes the controllers for doubly-fed induction generators (DFIG) with series grid side converter. It is demonstrated that with series grid side converter instead of a conventional shunt grid side converter the DFIG stator voltage can be kept balanced even under heavy unbalance grid voltages. Therefore, in this way it is avoided the undesired effects such as torque oscillations and high stator and rotor currents presents under unbalance voltages. In addition, it is demonstrated that it is possible with a conventional back-to-back three phase PWM converter to satisfy the grid code active and reactive power requirements. The design and control of the series grid-side converter with a LC-filter will also be presented. An Hinfin controller is designed to achieve robustness as well as good tracking and disturbance rejection performance for the series voltage converter. Furthermore, the DC-link, rotor currents and active and reactive power controllers are as well described, where the controllers transfer functions are selected to ensure good performance even in the presence of grid voltage unbalance. Finally, simulation results of a 2.27 MVA wind turbine generator are presented to demonstrate the good performance of the DFIG with the proposed controllers.Keywords
This publication has 13 references indexed in Scilit:
- Design and Comparison of High Performance Stationary-Frame Controllers for DVR ImplementationIEEE Transactions on Power Electronics, 2007
- Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network ConditionsIEEE Transactions on Power Systems, 2007
- Estruturas de sincronismo monofásica e trifásica baseadas no filtro de KalmanSba: Controle & Automação Sociedade Brasileira de Automatica, 2006
- New Scheme to Connect DFIG to Power GridIECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics, 2006
- Synchronisation method for three-phase PWM converters under unbalanced and distorted gridIEE Proceedings - Electric Power Applications, 2006
- Kalman filter based synchronization methods2006
- Assessment of voltage unbalanceIEEE Transactions on Power Delivery, 2001
- H/sub /spl infin// loop-shaping controller designs for the single-phase UPS invertersIEEE Transactions on Power Electronics, 2001
- Doubly fed induction generator usingback-to-back PWM convertersand its application to variable-speed wind-energy generationIEE Proceedings - Electric Power Applications, 1996
- A digital recursive measurement scheme for online tracking of power system harmonicsIEEE Transactions on Power Delivery, 1991