Research and Experimentation on the Orthogonal Error Correction Method for Horizontal Displacement Monitoring
Open Access
- 5 April 2024
- journal article
- Published by Acadlore Publishing Services Limited in Journal of Civil and Hydraulic Engineering
- Vol. 2 (2) , 75-86
Abstract
Dam deformation monitoring is a critical technical measure to ensure the safe and stable operation of dams. It involves measuring the structural deformation response of engineering dams using monitoring instruments or technological means. By analyzing the regularity and trend of deformation monitoring data, potential safety anomalies can be forecasted and warned against, providing timely and reliable data for the formulation and implementation of risk removal measures. Horizontal displacement, as the most intuitive and effective reflection of the dam's state under the action of internal and external loads and foundation deformation, is an indispensable part of dam safety monitoring. Currently, the plumb line method and the tensioned wire method are mainly used for horizontal displacement monitoring of dams. A plumb line coordinate instrument measures the horizontal deformation in the upstream and downstream directions and the left and right bank directions through two axes, or the radial and tangential horizontal displacements for arch dams. Compared to other principles, optoelectronic plumb line coordinate instruments have better long-term stability and anti-interference ability and are widely used on engineering sites. However, the orthogonality of the two measuring directions of the instrument is often overlooked. This paper starts from the principle of the development of the plumb line coordinate instrument, analyzes the source of instrument orthogonal error, and combines data collection, structural analysis, and experimental verification. By applying methods such as least squares and regression analysis, an effective calibration calculation and error correction method is proposed. This method is then programmed into the developed plumb line coordinate instrument to meet the real-time correction and output of measured values, providing a reliable technical method for the accuracy and continuous real-time remote monitoring of dam horizontal displacement monitoring. It also offers a technical path for the orthogonality testing of plumb line coordinate instruments.Keywords
Funding Information
- National Natural Science Foundation of China, Youth Science Fund Project (52209153)
This publication has 16 references indexed in Scilit:
- Electrical Monitoring in Diagnostics of the Soil Hydrotechnical Structures on the Example of Studying Earthfill DamPower Technology and Engineering, 2023
- Construction scheduling and monitoring control of dams based on BIMIOP Conference Series: Earth and Environmental Science, 2023
- Application of signal processing techniques in structural health monitoring of concrete gravity damsAsian Journal of Civil Engineering, 2023
- Seismic and structural health monitoring systems for large dams: theoretical, computational and practical innovationsBulletin of Earthquake Engineering, 2022
- An Online safety monitoring system of hydropower station based on expert systemEnergy Reports, 2022
- Prioritization of hydroelectric power plant earth dam safety procedures: a multi-criteria approachEnvironmental Earth Sciences, 2021
- The information domain confidence intervals in univariate linear calibrationCommunications in Statistics - Simulation and Computation, 2020
- Hysteretic effect considered monitoring model for interpreting abnormal deformation behavior of arch dams: A case studyStructural Control and Health Monitoring, 2019
- Investigation on Fast Response Performance of Dam Deformation Monitoring System with Wireless Sensor and Virtualizing TechniqueInternational Journal of Multimedia and Ubiquitous Engineering, 2016
- Technical report: Shell dam horizontal displacement monitoring – comparative study using geodetic measurement, optical plumb and GPS technologiesJournal of Applied Geodesy, 2009