Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning
- 11 January 2021
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 34 (1) , 149-161
Abstract
Deep learning (DL) has shown great potential in conversions between various imaging modalities. Similarly, DL can be applied to synthesize a high-kV computed tomography (CT) image from its corresponding low-kV CT image. This indicates the feasibility of obtaining dual-energy CT (DECT) images without purchasing a DECT scanner. In this study, we investigated whether a low-to-high kV mapping was better than a high-to-low kV mapping. We used a U-Net model to perform conversions between different kV CT images. Moreover, we proposed a double U-Net model to improve the quality of original single-energy CT images. Ninety-eight patients who underwent brain DECT scans were used to train, validate, and test the proposed DL-based model. The results showed that the low-to-high kV conversion was better than the high-to-low kV conversion. In addition, the DL-based DECT images had better signal-to-noise ratios (SNRs) than the true (original) DECT images, but at the expense of a slight loss in spatial resolution. The mean CT number differences between the true and DL-based DECT images were within \(\pm\) 1 HU. No statistically significant difference in CT number measurements was found between the true and DL-based DECT images (p > 0.05). The DL-based DECT images with improved SNR could produce low-noise virtual monoenergetic images. Our preliminary results indicate that DL has the potential to generate brain DECT images using single-energy brain CT images.
Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 109-2221-E-002-049)
This publication has 21 references indexed in Scilit:
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical ApplicationsRadiology, 2015
- Gibbs ringing in diffusion MRIMagnetic Resonance in Medicine, 2015
- CT Radiation Dose and Iterative Reconstruction TechniquesAmerican Journal of Roentgenology, 2015
- Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom studyPhysiological Measurement, 2014
- Dual-Energy CT: Radiation Dose AspectsAmerican Journal of Roentgenology, 2012
- Dual-Source Dual-Energy CT With Additional Tin Filtration: Dose and Image Quality Evaluation in Phantoms and In VivoAmerican Journal of Roentgenology, 2010
- Impact of new technologies on dose reduction in CTEuropean Journal of Radiology, 2010
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Training with Noise is Equivalent to Tikhonov RegularizationNeural Computation, 1995