Cytotoxicity and effects on metabolism of contact lens care solutions on human corneal epithelium cells
- 1 March 2012
- journal article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 95 (2) , 198-206
Abstract
Purpose: The aim was to determine the cytotoxic effects of three multipurpose solutions (MPS) on human corneal epithelial cells (HCEC) and to assess the metabolic rates of recovering cells at different levels of cell membrane damage. Method: The effects of one to 15 minutes exposure to multipurpose solutions containing polyquaternium-1 (MPS-A), polyaminopropyl biguanide (MPS-B) and polyhexanide (MPS-C) on HCEC were determined. Recovery rates at different levels of cell membrane damage were assessed after re-culture for two hours at 37°C. Cell viability and membrane integrity were assessed using Annexin V-FITC/7-AAD staining and flow cytometry. Effects of concentrations of 10 to 40 per cent multipurpose solutions on the metabolic rate of recovering HCEC were assessed using a Vybrant MTT cell proliferation assay kit. Results: The highest percentage of late necrotic cells resulted after exposure to MPS-A compared with other solutions and the control (p < 0.001). The percentages of early necrotic cells after 10 and 15 minutes of soaking in MPS-B were significantly higher than the control and other multipurpose solutions (p < 0.001). Although MPS-C exposure also resulted in statistically significant higher percentages of early necrotic cells than the control (p < 0.005), these differences were small. No recovery was noted when HCEC treated with multipurpose solutions were re-cultured, with numbers of dead cells in MPS-B-treated cultures increasing fourfold. The MTT assay showed significant dose-response decreases of 500 nm absorbance for all MPS-treated cells. In 40 per cent MPS-A-treated HCEC, lack of activity indicated the cells were non-viable. Conclusions: Multipurpose solutions induced varying levels of irreversible tissue sensitivity reactions, with MPS-A showing the greatest effects. The solutions damaged cell integrity and reduced metabolic rates suggesting delayed healing ability. The formulations of multipurpose solutions need to balance antimicrobial effectiveness with low cytotoxicity, which might not be currently possible to achieve. In light of our results, we suggest that contact lens wearers should be advised to rinse the soaked lenses with saline before lens insertion.Keywords
This publication has 32 references indexed in Scilit:
- Contact Lens Deposits, Adverse Responses, and Clinical Ocular Surface ParametersOptometry and Vision Science, 2010
- Contact lens user profile, attitudes and level of compliance to lens careContact Lens and Anterior Eye, 2010
- Contact Lens–Related Adverse Events and the Silicone Hydrogel Lenses and Daily Wear Care System UsedArchives of Ophthalmology (1950), 2009
- The effect of a compliance enhancement strategy (self‐review) on the level of lens care compliance and contamination of contact lenses and lens care accessoriesClinical and Experimental Optometry, 2007
- The comparative clinical performance of a new polyhexamethylene biguanide‐ vs a polyquad‐based contact lens care regime with two silicone hydrogel contact lensesOphthalmic and Physiological Optics, 2007
- Cytotoxicity and antimicrobial activity of six multipurpose soft contact lens disinfecting solutions 1Ophthalmic and Physiological Optics, 2006
- Clinical evaluation of a new multi-purpose disinfecting solution in symptomatic contact lens wearersContact Lens and Anterior Eye, 2006
- Incidence of contact-lens-associated microbial keratitis and its related morbidityThe Lancet, 1999
- Corneal Immune Ring as a Complication of Soft Extended Wear Contact Lens UseOptometry and Vision Science, 1991
- Corneal Ulcer and Adverse Reaction Rates in Premarket Contact Lens StudiesAmerican Journal of Ophthalmology, 1991