Abstract
Background: Ventricular tachycardia (VT) is a life-threatening heart condition commonly seen in patients with myocardial infarction (MI). Although personalized computational modeling has been used to understand VT and its treatment noninvasively, this approach can be computationally intensive and time consuming. Therefore, finding a balance between mesh size and computational efficiency is important. This study aimed to find an optimal mesh resolution that minimizes the need for computational resources while maintaining numerical accuracy and to investigate the effect of mesh resolution variation on the simulation results. Methods: We constructed ventricular models from contrast-enhanced magnetic resonance imaging data from six patients with MI. We created seven different models for each patient, with average edge lengths ranging from 315 to 645 µm using commercial software, Mimics. Programmed electrical stimulation was used to assess VT inducibility from 19 sites in each heart model. Results: The simulation results in the slab model with adaptive tetrahedral mesh (same as in the patient-specific model) showed that the absolute and relative differences in conduction velocity (CV) were 6.1 cm/s and 7.8% between average mesh sizes of 142 and 600 µm, respectively. However, the simulation results in the six patient-specific models showed that average mesh sizes with 350 µm yielded over 85% accuracy for clinically relevant VT. Although average mesh sizes of 417 and 478 µm could also achieve approximately 80% accuracy for clinically relevant VT, the percentage of incorrectly predicted VTs increases. When conductivity was modified to match the CV in the model with the finest mesh size, the overall ratio of positively predicted VT increased. Conclusions: The proposed personalized heart model could achieve an optimal balance between simulation time and VT prediction accuracy when discretized with adaptive tetrahedral meshes with an average edge length about 350 µm.Keywords
This publication has 44 references indexed in Scilit:
- Treatment Planning for Atrial Fibrillation Using Patient-Specific Models Showing the Importance of Fibrillatory-AreasAnnals of Biomedical Engineering, 2022
- Balancing conduction velocity error in cardiac electrophysiology using a modified quadrature approachInternational Journal for Numerical Methods in Biomedical Engineering, 2022
- The openCARP simulation environment for cardiac electrophysiologyComputer Methods and Programs in Biomedicine, 2021
- Fully Automatic Scar Segmentation for Late Gadolinium Enhancement MRI Images in Left Ventricle with Myocardial InfarctionCurrent Medical Science, 2021
- Characterizing Conduction Channels in Postinfarction Patients Using a Personalized Virtual HeartBiophysical Journal, 2019
- Pan-Asia United States PrEvention of Sudden Cardiac Death Catheter Ablation Trial (PAUSE-SCD): rationale and study designJournal of Interventional Cardiac Electrophysiology, 2019
- An adaptive hybridizable discontinuous Galerkin approach for cardiac electrophysiologyInternational Journal for Numerical Methods in Biomedical Engineering, 2018
- Space‐discretization error analysis and stabilization schemes for conduction velocity in cardiac electrophysiologyInternational Journal for Numerical Methods in Biomedical Engineering, 2015
- Modified wideband three‐dimensional late gadolinium enhancement MRI for patients with implantable cardiac devicesMagnetic Resonance in Medicine, 2015
- A Novel Rule-Based Algorithm for Assigning Myocardial Fiber Orientation to Computational Heart ModelsAnnals of Biomedical Engineering, 2012