Abstract
Aims: As implantation rates of leadless pacemakers (LPM) increase, a growing number of patients will require assessment of LPM removability. This multicentre study investigated the safety and feasibility of removal of tine-based LPMs. Methods and results: We retrospectively analysed consecutive patients who underwent tine-based LPM removal between March 2016 and January 2024 across 11 centres in Europe and the USA. Demographic characteristics, indication for LPM removal, procedural success, and complication rates were assessed. A total of 85 patients [median age 73 years (IQR 64–82)] were included. Indications for LPM removal included temporary use after transvenous lead extraction (23.5%), upgrade to a biventricular pacing system (22.4%) or a transvenous dual-chamber pacemaker (9.4%), and increased pacing thresholds (21.2%). The median device dwell time was 96 days (IQR 29–320 days), and the overall procedural success rate was 96.5%. In the majority of cases, removal was performed using a steerable sheath in combination with a single-loop snare. Procedure-related adverse events occurred in 5.9% of patients, including two pericardial effusions and three cases of device embolization. Significant predictors of removal failure (n = 3, 3.5%) were apical device position [odds ratio (OR) 61.8.0; 95% confidence interval (CI) 2.5–788716.3, P = 0.008] and longer device dwell time [OR 1.4; 95% CI 1.1–2.4, P = 0.008]. Conclusion: Removal of tine-based LPMs, typically after short- to mid-term device dwell times, was generally feasible and safe.Keywords
This publication has 69 references indexed in Scilit:
- Extraction of a 5-year-old leadless pacemaker using a competing manufacturer’s removal toolHeartRhythm Case Reports, 2023
- Leadless Pacing: Where We Currently Stand and What the Future HoldsCurrent Cardiology Reports, 2022
- The use of a needle’s eye snare to extract a leadless pacemaker in a patient with a persistent bacteremiaHeartRhythm Case Reports, 2022
- Retrieval of an infected leadless pacemakerHeartRhythm Case Reports, 2020
- Extraction of a “floating leadless pacemaker”: A case reportHeartRhythm Case Reports, 2020
- Extraction of a 4-year-old leadless pacemaker with a tine-based fixationHeartRhythm Case Reports, 2019
- Treating an infected transcatheter pacemaker system via percutaneous extractionHeartRhythm Case Reports, 2016
- Complete encapsulation of a leadless cardiac pacemakerClinical Research in Cardiology, 2015
- Post-cardiac injury syndrome following transvenous pacemaker insertion: A case report and review of the literatureHeart, Lung and Circulation, 2009
- The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leadsCardiovascular Pathology, 1995