Abstract
A simple strategy for the modification of disposable combination graphite-clay electrode, pencil graphite electrode (PGE), by multi-walled carbon nanotube–gold nanoparticle (MWNT–GNP) composite multilayers was proposed as a sensor to determine estradiol. The modification was carried out by the layer-by-layer (LBL) assembling of polyethyleneimine (PEI), decorated GNPs and polyacrylic acid (PAA) functionalised MWNTs via electrostatic interactions on a negatively charged PGE. The resulting MWNT–GNP multilayer modified PGE (MWNT–GNP/PGE) exhibited a sensitive electrochemical response towards the oxidation of estradiol at 0.90 V. Under optimal working conditions, the oxidation current of estradiol at MWNT–GNP/PGE increased linearly with its concentration in the range 7.0 × 10−8–4.2 × 10−5 mol l−1, with a low-detection limit of 1.0 × 10−8 mol l−1 for 200 s accumulation at an open circuit. This sensor was successfully applied to the detection of estradiol in blood serums.

This publication has 46 references indexed in Scilit: